| * Copyright 2017 Google Inc. |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| #include "pidloop.hpp" |
| |
| #include "pid/pidcontroller.hpp" |
| #include "pid/tuning.hpp" |
| #include "sensors/sensor.hpp" |
| |
| #include <boost/asio/steady_timer.hpp> |
| |
| #include <chrono> |
| #include <map> |
| #include <memory> |
| #include <thread> |
| #include <vector> |
| |
| namespace pid_control |
| { |
| |
| static void processThermals(PIDZone* zone) |
| { |
| // Get the latest margins. |
| zone->updateSensors(); |
| // Zero out the set point goals. |
| zone->clearSetPoints(); |
| zone->clearRPMCeilings(); |
| // Run the margin PIDs. |
| zone->processThermals(); |
| // Get the maximum RPM setpoint. |
| zone->determineMaxSetPointRequest(); |
| } |
| |
| void pidControlLoop(PIDZone* zone, boost::asio::steady_timer& timer, bool first, |
| int ms100cnt) |
| { |
| if (first) |
| { |
| if (loggingEnabled) |
| { |
| zone->initializeLog(); |
| } |
| |
| zone->initializeCache(); |
| processThermals(zone); |
| } |
| |
| timer.expires_after(std::chrono::milliseconds(100)); |
| timer.async_wait( |
| [zone, &timer, ms100cnt](const boost::system::error_code& ec) mutable { |
| if (ec == boost::asio::error::operation_aborted) |
| { |
| return; // timer being canceled, stop loop |
| } |
| |
| /* |
| * This should sleep on the conditional wait for the listen thread |
| * to tell us it's in sync. But then we also need a timeout option |
| * in case phosphor-hwmon is down, we can go into some weird failure |
| * more. |
| * |
| * Another approach would be to start all sensors in worst-case |
| * values, and fail-safe mode and then clear out of fail-safe mode |
| * once we start getting values. Which I think it is a solid |
| * approach. |
| * |
| * For now this runs before it necessarily has any sensor values. |
| * For the host sensors they start out in fail-safe mode. For the |
| * fans, they start out as 0 as input and then are adjusted once |
| * they have values. |
| * |
| * If a fan has failed, it's value will be whatever we're told or |
| * however we retrieve it. This program disregards fan values of 0, |
| * so any code providing a fan speed can set to 0 on failure and |
| * that fan value will be effectively ignored. The PID algorithm |
| * will be unhappy but nothing bad will happen. |
| * |
| * TODO(venture): If the fan value is 0 should that loop just be |
| * skipped? Right now, a 0 value is ignored in |
| * FanController::inputProc() |
| */ |
| |
| // Check if we should just go back to sleep. |
| if (zone->getManualMode()) |
| { |
| pidControlLoop(zone, timer, false, ms100cnt); |
| return; |
| } |
| |
| // Get the latest fan speeds. |
| zone->updateFanTelemetry(); |
| |
| if (10 <= ms100cnt) |
| { |
| ms100cnt = 0; |
| |
| processThermals(zone); |
| } |
| |
| // Run the fan PIDs every iteration. |
| zone->processFans(); |
| |
| if (loggingEnabled) |
| { |
| zone->getLogHandle() << "," << zone->getFailSafeMode(); |
| zone->getLogHandle() << std::endl; |
| } |
| |
| ms100cnt += 1; |
| |
| pidControlLoop(zone, timer, false, ms100cnt); |
| }); |
| } |
| |
| } // namespace pid_control |