#pragma once
#include "pid/ec/pid.hpp"
#include "pid/ec/stepwise.hpp"
#include <map>
#include <string>
#include <vector>
namespace conf
{
constexpr int64_t inheritValueFromDbus = std::numeric_limits<int64_t>::lowest();
/*
* General sensor structure used for configuration.
*/
struct SensorConfig
{
/* Used for listen if readPath is passive. */
std::string type;
/* Can be a sensor path or a dbus path. */
std::string readPath;
std::string writePath;
/* min/max values for writing a percentage or error checking. */
int64_t min;
int64_t max;
int64_t timeout;
};
/*
* Structure for holding the configuration of a PID.
*/
struct ControllerInfo
{
std::string type; // fan or margin or temp?
std::vector<std::string> inputs; // one or more sensors.
double setpoint; // initial setpoint for thermal.
union
{
ec::pidinfo pidInfo; // pid details
ec::StepwiseInfo stepwiseInfo;
};
};
/*
* General zone structure used for configuration. A zone is a list of PIDs
* and a set of configuration settings. This structure gets filled out with
* the zone configuration settings and not the PID details.
*/
struct ZoneConfig
{
/* The minimum RPM value we would ever want. */
double minThermalOutput;
/* If the sensors are in fail-safe mode, this is the percentage to use. */
double failsafePercent;
};
using PIDConf = std::map<std::string, struct ControllerInfo>;
} // namespace conf