blob: 8bf37cfac490fd6f18f1c17f9a46f8e7d4ee4733 [file] [log] [blame]
Patrick Venture391b8b02018-03-08 08:31:13 -08001This holds the source for the library we install to handle the manual control
2OEM IPMI command.
3
4The command is a simple series of bytes:
5[0] = Subcommand, Get(0) or Set(1), Get(2) for fail-safe mode.
6[1] = ZoneId
7[2] = Value if Set
8
9If Value == 1, then ManualMode is True and enabled, otherwise it's in normal
10mode.
11
12If Value == 1 (and Subcommand == 2), Failsafe mode is enabled, otherwise it's