| "comments": [ "phosphor-regulators configuration file for IBM Rainier systems" ], |
| |
| |
| "rules": [ |
| { |
| "comments": [ "Rule to set PMBus PAGE to 0" ], |
| "id": "set_page0_rule", |
| "actions": [ |
| { "i2c_write_byte": { "register": "0x00", "value": "0x00" } } |
| ] |
| }, |
| |
| |
| { |
| "comments": [ "Rule to set PMBus PAGE to 1" ], |
| "id": "set_page1_rule", |
| "actions": [ |
| { "i2c_write_byte": { "register": "0x00", "value": "0x01" } } |
| ] |
| }, |
| |
| |
| { |
| "comments": [ "Rule to set output voltage of a PMBus regulator" ], |
| "id": "set_voltage_rule", |
| "actions": [ |
| { |
| "comments": [ "Write volts value to VOUT_COMMAND in linear format.", |
| "Get volts value from configuration. Get exponent", |
| "from VOUT_MODE. Verify write was successful." ], |
| "pmbus_write_vout_command": { "format": "linear", "is_verified": true } |
| } |
| ] |
| }, |
| |
| |
| { |
| "comments": [ "Rule to set output voltage of PAGE 0 of a PMBus regulator" ], |
| "id": "set_voltage_page0_rule", |
| "actions": [ |
| { "run_rule": "set_page0_rule" }, |
| { "run_rule": "set_voltage_rule" } |
| ] |
| }, |
| |
| |
| { |
| "comments": [ "Rule to set output voltage of PAGE 1 of a PMBus regulator" ], |
| "id": "set_voltage_page1_rule", |
| "actions": [ |
| { "run_rule": "set_page1_rule" }, |
| { "run_rule": "set_voltage_rule" } |
| ] |
| } |
| ], |
| |
| |
| "chassis": [ |
| { |
| "comments": [ "Chassis (drawer) 1", |
| "Note: Devices not defined yet" ], |
| "number": 1, |
| "inventory_path": "system/chassis" |
| } |
| ] |
| } |