#include "psu_manager.hpp"
#include "utility.hpp"
#include <fmt/format.h>
#include <sys/types.h>
#include <unistd.h>
using namespace phosphor::logging;
namespace phosphor::power::manager
{
PSUManager::PSUManager(sdbusplus::bus::bus& bus, const sdeventplus::Event& e,
const std::string& configfile) :
bus(bus)
{
// Parse out the JSON properties
sys_properties properties;
getJSONProperties(configfile, bus, properties, psus);
using namespace sdeventplus;
auto interval = std::chrono::milliseconds(1000);
timer = std::make_unique<utility::Timer<ClockId::Monotonic>>(
e, std::bind(&PSUManager::analyze, this), interval);
minPSUs = {properties.minPowerSupplies};
maxPSUs = {properties.maxPowerSupplies};
// Subscribe to power state changes
powerService = util::getService(POWER_OBJ_PATH, POWER_IFACE, bus);
powerOnMatch = std::make_unique<sdbusplus::bus::match_t>(
bus,
sdbusplus::bus::match::rules::propertiesChanged(POWER_OBJ_PATH,
POWER_IFACE),
[this](auto& msg) { this->powerStateChanged(msg); });
initialize();
}
void PSUManager::getJSONProperties(
const std::string& path, sdbusplus::bus::bus& bus, sys_properties& p,
std::vector<std::unique_ptr<PowerSupply>>& psus)
{
nlohmann::json configFileJSON = util::loadJSONFromFile(path.c_str());
if (configFileJSON == nullptr)
{
throw std::runtime_error("Failed to load JSON configuration file");
}
if (!configFileJSON.contains("SystemProperties"))
{
throw std::runtime_error("Missing required SystemProperties");
}
if (!configFileJSON.contains("PowerSupplies"))
{
throw std::runtime_error("Missing required PowerSupplies");
}
auto sysProps = configFileJSON["SystemProperties"];
if (sysProps.contains("MinPowerSupplies"))
{
p.minPowerSupplies = sysProps["MinPowerSupplies"];
}
else
{
p.minPowerSupplies = 0;
}
if (sysProps.contains("MaxPowerSupplies"))
{
p.maxPowerSupplies = sysProps["MaxPowerSupplies"];
}
else
{
p.maxPowerSupplies = 0;
}
for (auto psuJSON : configFileJSON["PowerSupplies"])
{
if (psuJSON.contains("Inventory") && psuJSON.contains("Bus") &&
psuJSON.contains("Address"))
{
std::string invpath = psuJSON["Inventory"];
std::uint8_t i2cbus = psuJSON["Bus"];
std::string i2caddr = psuJSON["Address"];
auto psu =
std::make_unique<PowerSupply>(bus, invpath, i2cbus, i2caddr);
psus.emplace_back(std::move(psu));
}
else
{
log<level::ERR>("Insufficient PowerSupply properties");
}
}
if (psus.empty())
{
throw std::runtime_error("No power supplies to monitor");
}
}
void PSUManager::powerStateChanged(sdbusplus::message::message& msg)
{
int32_t state = 0;
std::string msgSensor;
std::map<std::string, std::variant<int32_t>> msgData;
msg.read(msgSensor, msgData);
// Check if it was the Present property that changed.
auto valPropMap = msgData.find("state");
if (valPropMap != msgData.end())
{
state = std::get<int32_t>(valPropMap->second);
// Power is on when state=1. Clear faults.
if (state)
{
powerOn = true;
clearFaults();
}
else
{
powerOn = false;
}
}
}
void PSUManager::createError(
const std::string& faultName,
const std::map<std::string, std::string>& additionalData)
{
using namespace sdbusplus::xyz::openbmc_project;
constexpr auto loggingObjectPath = "/xyz/openbmc_project/logging";
constexpr auto loggingCreateInterface =
"xyz.openbmc_project.Logging.Create";
try
{
auto service =
util::getService(loggingObjectPath, loggingCreateInterface, bus);
if (service.empty())
{
log<level::ERR>("Unable to get logging manager service");
return;
}
auto method = bus.new_method_call(service.c_str(), loggingObjectPath,
loggingCreateInterface, "Create");
auto level = Logging::server::Entry::Level::Error;
method.append(faultName, level, additionalData);
auto reply = bus.call(method);
}
catch (std::exception& e)
{
log<level::ERR>(
fmt::format(
"Failed creating event log for fault {} due to error {}",
faultName, e.what())
.c_str());
}
}
void PSUManager::analyze()
{
for (auto& psu : psus)
{
psu->analyze();
}
for (auto& psu : psus)
{
std::map<std::string, std::string> additionalData;
additionalData["_PID"] = std::to_string(getpid());
// TODO: Fault priorities #918
if (!psu->isFaultLogged() && !psu->isPresent())
{
// Create error for power supply missing.
additionalData["CALLOUT_INVENTORY_PATH"] = psu->getInventoryPath();
additionalData["CALLOUT_PRIORITY"] = "H";
createError("xyz.openbmc_project.Power.PowerSupply.Error.Missing",
additionalData);
psu->setFaultLogged();
}
else if (!psu->isFaultLogged() && psu->isFaulted())
{
additionalData["STATUS_WORD"] =
std::to_string(psu->getStatusWord());
// If there are faults being reported, they possibly could be
// related to a bug in the firmware version running on the power
// supply. Capture that data into the error as well.
additionalData["FW_VERSION"] = psu->getFWVersion();
if ((psu->hasInputFault() || psu->hasVINUVFault()))
{
/* The power supply location might be needed if the input fault
* is due to a problem with the power supply itself. Include the
* inventory path with a call out priority of low.
*/
additionalData["CALLOUT_INVENTORY_PATH"] =
psu->getInventoryPath();
additionalData["CALLOUT_PRIORITY"] = "L";
createError(
"xyz.openbmc_project.Power.PowerSupply.Error.InputFault",
additionalData);
psu->setFaultLogged();
}
else if (psu->hasMFRFault())
{
/* This can represent a variety of faults that result in calling
* out the power supply for replacement:
* Output OverCurrent, Output Under Voltage, and potentially
* other faults.
*
* Also plan on putting specific fault in AdditionalData,
* along with register names and register values
* (STATUS_WORD, STATUS_MFR, etc.).*/
additionalData["CALLOUT_INVENTORY_PATH"] =
psu->getInventoryPath();
createError("xyz.openbmc_project.Power.PowerSupply.Error.Fault",
additionalData);
psu->setFaultLogged();
}
else if (psu->hasCommFault())
{
/* Attempts to communicate with the power supply have reached
* there limit. Create an error. */
additionalData["CALLOUT_DEVICE_PATH"] = psu->getDevicePath();
createError(
"xyz.openbmc_project.Power.PowerSupply.Error.CommFault",
additionalData);
psu->setFaultLogged();
}
}
}
}
} // namespace phosphor::power::manager