| * Copyright © 2024 IBM Corporation |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| #include "mock_pmbus.hpp" |
| #include "mock_services.hpp" |
| #include "pmbus.hpp" |
| #include "rail.hpp" |
| #include "services.hpp" |
| #include "ucd90160_device.hpp" |
| |
| #include <cstdint> |
| #include <map> |
| #include <memory> |
| #include <optional> |
| #include <string> |
| #include <utility> |
| #include <vector> |
| |
| #include <gmock/gmock.h> |
| #include <gtest/gtest.h> |
| |
| using namespace phosphor::power::sequencer; |
| using namespace phosphor::pmbus; |
| |
| using ::testing::Return; |
| |
| /** |
| * Creates a Rail object that checks for a pgood fault using a GPIO. |
| * |
| * @param name Unique name for the rail |
| * @param gpio GPIO line to read to determine the pgood status of the rail |
| * @return Rail object |
| */ |
| static std::unique_ptr<Rail> createRail(const std::string& name, |
| unsigned int gpioLine) |
| { |
| std::optional<std::string> presence{}; |
| std::optional<uint8_t> page{}; |
| bool isPowerSupplyRail{false}; |
| bool checkStatusVout{false}; |
| bool compareVoltageToLimit{false}; |
| bool activeLow{false}; |
| std::optional<GPIO> gpio{GPIO{gpioLine, activeLow}}; |
| return std::make_unique<Rail>(name, presence, page, isPowerSupplyRail, |
| checkStatusVout, compareVoltageToLimit, gpio); |
| } |
| |
| TEST(UCD90160DeviceTests, Constructor) |
| { |
| MockServices services; |
| |
| std::vector<std::unique_ptr<Rail>> rails; |
| rails.emplace_back(createRail("VDD", 5)); |
| rails.emplace_back(createRail("VIO", 7)); |
| uint8_t bus{3}; |
| uint16_t address{0x72}; |
| UCD90160Device device{std::move(rails), services, bus, address}; |
| |
| EXPECT_EQ(device.getName(), "UCD90160"); |
| EXPECT_EQ(device.getRails().size(), 2); |
| EXPECT_EQ(device.getRails()[0]->getName(), "VDD"); |
| EXPECT_EQ(device.getRails()[1]->getName(), "VIO"); |
| EXPECT_EQ(device.getBus(), bus); |
| EXPECT_EQ(device.getAddress(), address); |
| EXPECT_EQ(device.getDriverName(), "ucd9000"); |
| EXPECT_EQ(device.getInstance(), 0); |
| EXPECT_NE(&(device.getPMBusInterface()), nullptr); |
| } |
| |
| TEST(UCD90160DeviceTests, StoreGPIOValues) |
| { |
| // This is a protected method and cannot be called directly from a gtest. |
| // Call findPgoodFault() which calls storeGPIOValues(). |
| |
| // Test where works |
| { |
| std::vector<int> gpioValues{ |
| 1, 0, 0, 1, // group 1 in journal |
| 1, 1, 0, 0, // group 2 in journal |
| 1, 0, 1, 1, // group 3 in journal |
| 0, 0, 1, 1, // group 4 in journal |
| 1, 0, 0, 0, // group 5 in journal |
| 1, 0, 0, 1, // group 6 in journal |
| 1, 1 // group 7 in journal |
| }; |
| |
| MockServices services; |
| EXPECT_CALL(services, getGPIOValues("ucd90160")) |
| .Times(1) |
| .WillOnce(Return(gpioValues)); |
| EXPECT_CALL(services, logInfoMsg("Device UCD90160 GPIO values:")) |
| .Times(1); |
| EXPECT_CALL(services, |
| logInfoMsg( |
| "[FPWM1_GPIO5, FPWM2_GPIO6, FPWM3_GPIO7, FPWM4_GPIO8]: " |
| "[1, 0, 0, 1]")) |
| .Times(1); |
| EXPECT_CALL( |
| services, |
| logInfoMsg( |
| "[FPWM5_GPIO9, FPWM6_GPIO10, FPWM7_GPIO11, FPWM8_GPIO12]: " |
| "[1, 1, 0, 0]")) |
| .Times(1); |
| EXPECT_CALL(services, |
| logInfoMsg("[GPI1_PWM1, GPI2_PWM2, GPI3_PWM3, GPI4_PWM4]: " |
| "[1, 0, 1, 1]")) |
| .Times(1); |
| EXPECT_CALL(services, |
| logInfoMsg("[GPIO14, GPIO15, TDO_GPIO20, TCK_GPIO19]: " |
| "[0, 0, 1, 1]")) |
| .Times(1); |
| EXPECT_CALL(services, |
| logInfoMsg("[TMS_GPIO22, TDI_GPIO21, GPIO1, GPIO2]: " |
| "[1, 0, 0, 0]")) |
| .Times(1); |
| EXPECT_CALL(services, logInfoMsg("[GPIO3, GPIO4, GPIO13, GPIO16]: " |
| "[1, 0, 0, 1]")) |
| .Times(1); |
| EXPECT_CALL(services, logInfoMsg("[GPIO17, GPIO18]: " |
| "[1, 1]")) |
| .Times(1); |
| EXPECT_CALL(services, |
| logInfoMsg("Device UCD90160 MFR_STATUS: 0x123456789abc")) |
| .Times(1); |
| EXPECT_CALL( |
| services, |
| logErrorMsg( |
| "Pgood fault found in rail monitored by device UCD90160")) |
| .Times(1); |
| EXPECT_CALL(services, logErrorMsg("Pgood fault detected in rail VDD")) |
| .Times(1); |
| EXPECT_CALL( |
| services, |
| logErrorMsg( |
| "Rail VDD pgood GPIO line offset 2 has inactive value 0")) |
| .Times(1); |
| |
| std::vector<std::unique_ptr<Rail>> rails; |
| rails.emplace_back(createRail("VDD", 2)); |
| uint8_t bus{3}; |
| uint16_t address{0x72}; |
| UCD90160Device device{std::move(rails), services, bus, address}; |
| |
| MockPMBus& pmbus = static_cast<MockPMBus&>(device.getPMBusInterface()); |
| EXPECT_CALL(pmbus, getPath(Type::Hwmon)) |
| .Times(1) |
| .WillOnce(Return("/tmp")); |
| EXPECT_CALL(pmbus, read("mfr_status", Type::HwmonDeviceDebug, true)) |
| .Times(1) |
| .WillOnce(Return(0x123456789abcull)); |
| |
| // Call findPgoodFault() which calls storeGPIOValues() |
| std::string powerSupplyError{}; |
| std::map<std::string, std::string> additionalData{}; |
| std::string error = |
| device.findPgoodFault(services, powerSupplyError, additionalData); |
| EXPECT_EQ(error, |
| "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault"); |
| EXPECT_EQ(additionalData.size(), 31); |
| EXPECT_EQ(additionalData["MFR_STATUS"], "0x123456789abc"); |
| EXPECT_EQ(additionalData["DEVICE_NAME"], "UCD90160"); |
| EXPECT_EQ(additionalData["FPWM1_GPIO5"], "1"); |
| EXPECT_EQ(additionalData["FPWM2_GPIO6"], "0"); |
| EXPECT_EQ(additionalData["FPWM3_GPIO7"], "0"); |
| EXPECT_EQ(additionalData["FPWM4_GPIO8"], "1"); |
| EXPECT_EQ(additionalData["FPWM5_GPIO9"], "1"); |
| EXPECT_EQ(additionalData["FPWM6_GPIO10"], "1"); |
| EXPECT_EQ(additionalData["FPWM7_GPIO11"], "0"); |
| EXPECT_EQ(additionalData["FPWM8_GPIO12"], "0"); |
| EXPECT_EQ(additionalData["GPI1_PWM1"], "1"); |
| EXPECT_EQ(additionalData["GPI2_PWM2"], "0"); |
| EXPECT_EQ(additionalData["GPI3_PWM3"], "1"); |
| EXPECT_EQ(additionalData["GPI4_PWM4"], "1"); |
| EXPECT_EQ(additionalData["GPIO14"], "0"); |
| EXPECT_EQ(additionalData["GPIO15"], "0"); |
| EXPECT_EQ(additionalData["TDO_GPIO20"], "1"); |
| EXPECT_EQ(additionalData["TCK_GPIO19"], "1"); |
| EXPECT_EQ(additionalData["TMS_GPIO22"], "1"); |
| EXPECT_EQ(additionalData["TDI_GPIO21"], "0"); |
| EXPECT_EQ(additionalData["GPIO1"], "0"); |
| EXPECT_EQ(additionalData["GPIO2"], "0"); |
| EXPECT_EQ(additionalData["GPIO3"], "1"); |
| EXPECT_EQ(additionalData["GPIO4"], "0"); |
| EXPECT_EQ(additionalData["GPIO13"], "0"); |
| EXPECT_EQ(additionalData["GPIO16"], "1"); |
| EXPECT_EQ(additionalData["GPIO17"], "1"); |
| EXPECT_EQ(additionalData["GPIO18"], "1"); |
| EXPECT_EQ(additionalData["RAIL_NAME"], "VDD"); |
| EXPECT_EQ(additionalData["GPIO_LINE"], "2"); |
| EXPECT_EQ(additionalData["GPIO_VALUE"], "0"); |
| } |
| |
| // Test where there are the wrong number of GPIOs (27 instead of 26) |
| { |
| std::vector<int> gpioValues{ |
| 1, 0, 0, 1, // group 1 in journal |
| 1, 1, 0, 0, // group 2 in journal |
| 1, 0, 1, 1, // group 3 in journal |
| 0, 0, 1, 1, // group 4 in journal |
| 1, 0, 0, 0, // group 5 in journal |
| 1, 0, 0, 1, // group 6 in journal |
| 1, 1, 0 // group 7 in journal + extra value |
| }; |
| |
| MockServices services; |
| EXPECT_CALL(services, getGPIOValues("ucd90160")) |
| .Times(1) |
| .WillOnce(Return(gpioValues)); |
| EXPECT_CALL(services, |
| logInfoMsg("Device UCD90160 GPIO values: [" |
| "1, 0, 0, 1, " |
| "1, 1, 0, 0, " |
| "1, 0, 1, 1, " |
| "0, 0, 1, 1, " |
| "1, 0, 0, 0, " |
| "1, 0, 0, 1, " |
| "1, 1, 0]")) |
| .Times(1); |
| EXPECT_CALL(services, |
| logInfoMsg("Device UCD90160 MFR_STATUS: 0x123456789abc")) |
| .Times(1); |
| EXPECT_CALL( |
| services, |
| logErrorMsg( |
| "Pgood fault found in rail monitored by device UCD90160")) |
| .Times(1); |
| EXPECT_CALL(services, logErrorMsg("Pgood fault detected in rail VDD")) |
| .Times(1); |
| EXPECT_CALL( |
| services, |
| logErrorMsg( |
| "Rail VDD pgood GPIO line offset 2 has inactive value 0")) |
| .Times(1); |
| |
| std::vector<std::unique_ptr<Rail>> rails; |
| rails.emplace_back(createRail("VDD", 2)); |
| uint8_t bus{3}; |
| uint16_t address{0x72}; |
| UCD90160Device device{std::move(rails), services, bus, address}; |
| |
| MockPMBus& pmbus = static_cast<MockPMBus&>(device.getPMBusInterface()); |
| EXPECT_CALL(pmbus, getPath(Type::Hwmon)) |
| .Times(1) |
| .WillOnce(Return("/tmp")); |
| EXPECT_CALL(pmbus, read("mfr_status", Type::HwmonDeviceDebug, true)) |
| .Times(1) |
| .WillOnce(Return(0x123456789abcull)); |
| |
| // Call findPgoodFault() which calls storeGPIOValues() |
| std::string powerSupplyError{}; |
| std::map<std::string, std::string> additionalData{}; |
| std::string error = |
| device.findPgoodFault(services, powerSupplyError, additionalData); |
| EXPECT_EQ(error, |
| "xyz.openbmc_project.Power.Error.PowerSequencerVoltageFault"); |
| EXPECT_EQ(additionalData.size(), 6); |
| EXPECT_EQ(additionalData["MFR_STATUS"], "0x123456789abc"); |
| EXPECT_EQ(additionalData["DEVICE_NAME"], "UCD90160"); |
| EXPECT_EQ(additionalData["GPIO_VALUES"], |
| "[1, 0, 0, 1, " |
| "1, 1, 0, 0, " |
| "1, 0, 1, 1, " |
| "0, 0, 1, 1, " |
| "1, 0, 0, 0, " |
| "1, 0, 0, 1, " |
| "1, 1, 0]"); |
| EXPECT_EQ(additionalData["RAIL_NAME"], "VDD"); |
| EXPECT_EQ(additionalData["GPIO_LINE"], "2"); |
| EXPECT_EQ(additionalData["GPIO_VALUE"], "0"); |
| } |
| } |