commit | 72e584c5bae66b00a55e513dffc410e510348c26 | [log] [tgz] |
---|---|---|
author | Anwaar Hadi <anwaar.hadi@ibm.com> | Tue May 20 22:02:14 2025 +0000 |
committer | Shawn McCarney <shawnmm@us.ibm.com> | Thu May 29 17:55:52 2025 +0000 |
tree | 8ac034f1df7dcc60216aa653f1eab7a96aaadacb | |
parent | 3cf72398daff3a5d53c23373ae43112f436d1fe8 [diff] |
Move phosphor-regulators, tools, base dir to lg2 Update the logging API for files in phosphor-regulators, tools, and the base directory from the older phosphor::logging::log style of journal traces to the newer lg2::log style. Also fix bug involving corruption of string data in PMBus class. Tested: * Verified journal traces worked correctly in simulation and produced correct journalctl key-value pairs. * Temporarily modified both json configs and source code to force various messages, and verified their presence in the journalctl output. * Verify that change in PMBus class correctly fixed corrupted string data by building and running a temporary executable with the change included. Change-Id: I9c3e380bf2103c5ddc051a5dc90ba2c0d3f38796 Signed-off-by: Anwaar Hadi <anwaar.hadi@ibm.com>
This repository contains applications for configuring and monitoring devices that deliver power to the system.
Actively-maintained applications:
Legacy applications:
To build all applications in this repository:
meson setup build ninja -C build
To clean the repository and remove all build output:
rm -rf build
You can specify meson options to customize the build process. For example, you can specify:
Several applications in this repository require a PSU JSON config to run. The JSON config file provides information for:
There is an example psu.json to describe the necessary configurations.
inventoryPMBusAccessType
defines the pmbus access type, which tells the service which sysfs type to use to read the attributes. The possible values are:
/sys/bus/i2c/devices/3-0069/
/sys/bus/i2c/devices/3-0069/hwmon/hwmonX/
/sys/kernel/debug/pmbus/hwmonX/
/sys/kernel/debug/<driver>.<instance>/
/sys/kernel/debug/pmbus/hwmonX/cffps1/
fruConfigs
defines the mapping between the attribute file and the FRU inventory interface and property. The configuration example below indicates that the service will read part_number
attribute file from a directory specified by the above pmbus access type, and assign to PartNumber
property in xyz.openbmc_project.Inventory.Decorator.Asset
interface.
"fruConfigs": [ { "propertyName": "PartNumber", "fileName": "part_number", "interface": "xyz.openbmc_project.Inventory.Decorator.Asset" } ]
psuDevices
defines the kernel device dir for each PSU in inventory. The configuration example below indicates that powersupply0
's device is located in /sys/bus/i2c/devices/3-0069
.
"psuDevices": { "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0" : "/sys/bus/i2c/devices/3-0069", }