| * Copyright © 2025 IBM Corporation |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| |
| #pragma once |
| |
| #include "types.hpp" |
| #include "utility.hpp" |
| |
| #include <sdbusplus/bus.hpp> |
| |
| #include <string> |
| |
| namespace validator |
| { |
| using namespace phosphor::power::util; |
| /** |
| * @class PSUUpdateValidator |
| * @brief This class validates PSU configurations in OpenBMC. |
| */ |
| class PSUUpdateValidator |
| { |
| public: |
| /** |
| * @brief Constructor - Initializes D-Bus connection. |
| * |
| * @param bus The sdbusplus DBus bus connection |
| * @param psuPath PSU inventory path |
| */ |
| PSUUpdateValidator(sdbusplus::bus_t& bus, const std::string& psuPath) : |
| bus(bus), psuPath(psuPath) |
| {} |
| |
| /** |
| * @brief Checks if all PSUs are of the same model. |
| * |
| * @return true if all PSUs have the same model. |
| * @return false if any PSU has a different model. |
| */ |
| bool areAllPsuSameModel(); |
| |
| /** |
| * @brief Counts the number of PSUs that are physically present and |
| * operational |
| * |
| * @return true if successfully counted present PSUs. |
| * @return false on failure. |
| */ |
| bool countPresentPsus(); |
| |
| /** |
| * @brief Retrieves the required number of PSUs for redundancy. |
| * |
| * @return true if successfully retrieved redundancy count. |
| * @return false on failure. |
| */ |
| bool getRequiredPsus(); |
| |
| /** |
| * @brief Ensure all PSUs have same model, validate all PSUs present |
| * and functional meet or exceed the number of PSUs required for this |
| * system |
| * |
| * @return true if all configuration requirement are met. |
| * @return otherwise false |
| */ |
| bool validToUpdate(); |
| |
| /** |
| * @brief Retrieves the operational PSU status. |
| * |
| * @return true if operational |
| * @return false on operational failure. |
| */ |
| bool isItFunctional(const std::string& path); |
| |
| private: |
| sdbusplus::bus_t& bus; // D-Bus connection instance |
| std::vector<std::string> psuPaths; // List of PSU object paths |
| std::string targetPsuModel; // Model name of the reference PSU |
| std::string psuPath; // Path of the referenced PSU |
| DbusSubtree supportedObjects; // D-Bus PSU supported objects |
| DbusPropertyMap properties; // D-Bus PSU properties |
| int presentPsuCount = 0; // Count of physically present PSUs |
| int redundantCount = 0; // Total number of PSUs required to be |
| // in this system configuration. |
| }; |
| |
| } // namespace validator |