| Shawn McCarney | 6663abf | 2020-02-29 17:25:48 -0600 | [diff] [blame] | 1 | /** | 
|  | 2 | * Copyright © 2020 IBM Corporation | 
|  | 3 | * | 
|  | 4 | * Licensed under the Apache License, Version 2.0 (the "License"); | 
|  | 5 | * you may not use this file except in compliance with the License. | 
|  | 6 | * You may obtain a copy of the License at | 
|  | 7 | * | 
|  | 8 | *     http://www.apache.org/licenses/LICENSE-2.0 | 
|  | 9 | * | 
|  | 10 | * Unless required by applicable law or agreed to in writing, software | 
|  | 11 | * distributed under the License is distributed on an "AS IS" BASIS, | 
|  | 12 | * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. | 
|  | 13 | * See the License for the specific language governing permissions and | 
|  | 14 | * limitations under the License. | 
|  | 15 | */ | 
|  | 16 | #pragma once | 
|  | 17 |  | 
|  | 18 | #include <cmath> | 
|  | 19 | #include <cstdint> | 
|  | 20 |  | 
|  | 21 | /** | 
|  | 22 | * @namespace pmbus_utils | 
|  | 23 | * | 
|  | 24 | * Contains utilities for sending PMBus commands over an I2C interface. | 
|  | 25 | */ | 
|  | 26 | namespace phosphor::power::regulators::pmbus_utils | 
|  | 27 | { | 
|  | 28 |  | 
|  | 29 | /* | 
|  | 30 | * PMBus command codes. | 
|  | 31 | * | 
|  | 32 | * The constant names are all uppercase to match the PMBus documentation. | 
|  | 33 | * | 
|  | 34 | * Only the commands that are currently used by this application are defined. | 
|  | 35 | * See the PMBus documentation for all valid command codes. | 
|  | 36 | */ | 
|  | 37 | const uint8_t VOUT_MODE{0x20u}; | 
|  | 38 | const uint8_t VOUT_COMMAND{0x21u}; | 
|  | 39 |  | 
|  | 40 | /** | 
|  | 41 | * Data formats for output voltage. | 
|  | 42 | * | 
|  | 43 | * These formats are used for commanding and reading output voltage and related | 
|  | 44 | * parameters. | 
|  | 45 | */ | 
|  | 46 | enum class VoutDataFormat | 
|  | 47 | { | 
|  | 48 | /** | 
|  | 49 | * Linear scale that uses a two byte unsigned binary integer with a scaling | 
|  | 50 | * factor. | 
|  | 51 | */ | 
|  | 52 | linear, | 
|  | 53 |  | 
|  | 54 | /** | 
|  | 55 | * Format that supports transmitting VID codes. | 
|  | 56 | */ | 
|  | 57 | vid, | 
|  | 58 |  | 
|  | 59 | /** | 
|  | 60 | * Direct format that uses an equation and device supplied coefficients. | 
|  | 61 | */ | 
|  | 62 | direct, | 
|  | 63 |  | 
|  | 64 | /** | 
|  | 65 | * Half-precision floating point format that follows the IEEE-754 standard | 
|  | 66 | * for representing magnitudes in 16 bits. | 
|  | 67 | */ | 
|  | 68 | ieee | 
|  | 69 | }; | 
|  | 70 |  | 
|  | 71 | /** | 
|  | 72 | * Parse the one byte value of the VOUT_MODE command. | 
|  | 73 | * | 
|  | 74 | * VOUT_MODE contains a 'mode' field that indicates the data format used for | 
|  | 75 | * output voltage values. | 
|  | 76 | * | 
|  | 77 | * VOUT_MODE also contains a 'parameter' field whose value is dependent on the | 
|  | 78 | * data format: | 
|  | 79 | *  - Linear format: value is an exponent | 
|  | 80 | *  - VID format: value is a VID code | 
|  | 81 | *  - IEEE and Direct formats: value is not used | 
|  | 82 | * | 
|  | 83 | * @param voutModeValue one byte value of VOUT_MODE command | 
|  | 84 | * @param format data format from the 'mode' field | 
|  | 85 | * @param parameter parameter value from the 'parameter' field | 
|  | 86 | */ | 
|  | 87 | void parseVoutMode(uint8_t voutModeValue, VoutDataFormat& format, | 
|  | 88 | int8_t& parameter); | 
|  | 89 |  | 
|  | 90 | /** | 
|  | 91 | * Converts a volts value to the linear data format for output voltage. | 
|  | 92 | * | 
|  | 93 | * This data format consists of the following: | 
|  | 94 | *   - Two byte value | 
|  | 95 | *   - 16-bit unsigned mantissa value stored in the two bytes | 
|  | 96 | *   - 5-bit signed exponent value that is not stored in the two bytes | 
|  | 97 | * | 
|  | 98 | * The exponent value is typically obtained from the PMBus VOUT_MODE command | 
|  | 99 | * or from the hardware device documentation (data sheet). | 
|  | 100 | * | 
|  | 101 | * Note that this format differs from the linear data format for values | 
|  | 102 | * unrelated to output voltage. | 
|  | 103 | * | 
|  | 104 | * @param volts volts value to convert; must not be negative | 
|  | 105 | * @param exponent 5-bit signed exponent used to convert value | 
|  | 106 | * @return linear data format value | 
|  | 107 | */ | 
|  | 108 | inline uint16_t convertToVoutLinear(double volts, int8_t exponent) | 
|  | 109 | { | 
|  | 110 | // Obtain mantissa using equation 'mantissa = volts / 2^exponent' | 
|  | 111 | double mantissa = volts / std::pow(2.0, static_cast<double>(exponent)); | 
|  | 112 |  | 
|  | 113 | // Return the mantissa value after converting to a rounded uint16_t | 
|  | 114 | return static_cast<uint16_t>(std::lround(mantissa)); | 
|  | 115 | } | 
|  | 116 |  | 
|  | 117 | } // namespace phosphor::power::regulators::pmbus_utils |