blob: ea038741dec446484c65bdbea9f123d4fd513c05 [file] [log] [blame]
{
"entries": [
{
"attribute_name": "pvm_system_name",
"string_type": "ASCII",
"minimum_string_length": 0,
"maximum_string_length": 100,
"default_string_length": 0,
"default_string": "",
"helpText": "pvm_system_name",
"displayName": "pvm_system_name",
"dbus": {
"object_path": "/xyz/openbmc_project/inventory/system",
"interface": "xyz.openbmc_project.Inventory.Decorator.AssetTag",
"property_name": "AssetTag",
"property_type": "string"
}
},
{
"attribute_name": "vmi_hostname",
"string_type": "ASCII",
"minimum_string_length": 0,
"maximum_string_length": 255,
"default_string_length": 0,
"default_string": "",
"helpText": "vmi_hostname",
"displayName": "vmi_hostname"
},
{
"attribute_name": "vmi_if0_ipv4_gateway",
"string_type": "ASCII",
"minimum_string_length": 7,
"maximum_string_length": 15,
"default_string_length": 7,
"default_string": "0.0.0.0",
"helpText": "vmi_if0_ipv4_gateway",
"displayName": "vmi_if0_ipv4_gateway"
},
{
"attribute_name": "vmi_if1_ipv4_gateway",
"string_type": "ASCII",
"minimum_string_length": 7,
"maximum_string_length": 15,
"default_string_length": 7,
"default_string": "0.0.0.0",
"helpText": "vmi_if1_ipv4_gateway",
"displayName": "vmi_if1_ipv4_gateway"
},
{
"attribute_name": "vmi_if0_ipv4_ipaddr",
"string_type": "ASCII",
"minimum_string_length": 7,
"maximum_string_length": 15,
"default_string_length": 7,
"default_string": "0.0.0.0",
"helpText": "vmi_if0_ipv4_ipaddr",
"displayName": "vmi_if0_ipv4_ipaddr"
},
{
"attribute_name": "vmi_if1_ipv4_ipaddr",
"string_type": "ASCII",
"minimum_string_length": 7,
"maximum_string_length": 15,
"default_string_length": 7,
"default_string": "0.0.0.0",
"helpText": "vmi_if1_ipv4_ipaddr",
"displayName": "vmi_if1_ipv4_ipaddr"
},
{
"attribute_name": "vmi_if0_ipv6_gateway",
"string_type": "ASCII",
"minimum_string_length": 2,
"maximum_string_length": 45,
"default_string_length": 2,
"default_string": "::",
"helpText": "vmi_if0_ipv6_gateway",
"displayName": "vmi_if0_ipv6_gateway"
},
{
"attribute_name": "vmi_if1_ipv6_gateway",
"string_type": "ASCII",
"minimum_string_length": 2,
"maximum_string_length": 45,
"default_string_length": 2,
"default_string": "::",
"helpText": "vmi_if1_ipv6_gateway",
"displayName": "vmi_if1_ipv6_gateway"
},
{
"attribute_name": "vmi_if0_ipv6_ipaddr",
"string_type": "ASCII",
"minimum_string_length": 2,
"maximum_string_length": 45,
"default_string_length": 2,
"default_string": "::",
"helpText": "vmi_if0_ipv6_ipaddr",
"displayName": "vmi_if0_ipv6_ipaddr"
},
{
"attribute_name": "vmi_if1_ipv6_ipaddr",
"string_type": "ASCII",
"minimum_string_length": 2,
"maximum_string_length": 45,
"default_string_length": 2,
"default_string": "::",
"helpText": "vmi_if1_ipv6_ipaddr",
"displayName": "vmi_if1_ipv6_ipaddr"
},
{
"attribute_name": "hb_mfg_flags",
"string_type": "Hex",
"minimum_string_length": 32,
"maximum_string_length": 32,
"default_string_length": 32,
"default_string": "00000000000000000000000000000000",
"helpText": "Specifies the configuration flags used by manufacturing, requires a reboot for a change to be applied.",
"displayName": "Manufacturing Flags (pending)"
},
{
"attribute_name": "hb_mfg_flags_current",
"string_type": "Hex",
"minimum_string_length": 32,
"maximum_string_length": 32,
"default_string_length": 32,
"default_string": "00000000000000000000000000000000",
"helpText": "Specifies the configuration flags used by manufacturing for the current IPL. Do not set this attribute directly; set hb_mfg_flags instead.",
"displayName": "Manufacturing Flags (current)",
"readOnly": true
},
{
"attribute_name": "hb_lid_ids",
"string_type": "ASCII",
"minimum_string_length": 0,
"maximum_string_length": 1024,
"default_string_length": 0,
"default_string": "",
"helpText": "Provides the host a mapping of the lid IDs to human readable names.",
"displayName": "Hostboot Lid IDs"
},
{
"attribute_name": "hb_power_PS0_model",
"string_type": "ASCII",
"minimum_string_length": 0,
"maximum_string_length": 4,
"default_string_length": 4,
"default_string": "0000",
"helpText": "Specifies the power supply 0 model CCIN in hex.",
"displayName": "Power Supply 0 Model",
"dbus": {
"object_path": "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply0",
"interface": "xyz.openbmc_project.Inventory.Decorator.Asset",
"property_type": "string",
"property_name": "Model"
}
},
{
"attribute_name": "hb_power_PS1_model",
"string_type": "ASCII",
"minimum_string_length": 0,
"maximum_string_length": 4,
"default_string_length": 4,
"default_string": "0000",
"helpText": "Specifies the power supply 1 model CCIN in hex.",
"displayName": "Power Supply 1 Model",
"dbus": {
"object_path": "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply1",
"interface": "xyz.openbmc_project.Inventory.Decorator.Asset",
"property_type": "string",
"property_name": "Model"
}
},
{
"attribute_name": "hb_power_PS2_model",
"string_type": "ASCII",
"minimum_string_length": 0,
"maximum_string_length": 4,
"default_string_length": 4,
"default_string": "0000",
"helpText": "Specifies the power supply 2 model CCIN in hex.",
"displayName": "Power Supply 2 Model",
"dbus": {
"object_path": "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply2",
"interface": "xyz.openbmc_project.Inventory.Decorator.Asset",
"property_type": "string",
"property_name": "Model"
}
},
{
"attribute_name": "hb_power_PS3_model",
"string_type": "ASCII",
"minimum_string_length": 0,
"maximum_string_length": 4,
"default_string_length": 4,
"default_string": "0000",
"helpText": "Specifies the power supply 3 model CCIN in hex.",
"displayName": "Power Supply 3 Model",
"dbus": {
"object_path": "/xyz/openbmc_project/inventory/system/chassis/motherboard/powersupply3",
"interface": "xyz.openbmc_project.Inventory.Decorator.Asset",
"property_type": "string",
"property_name": "Model"
}
}
]
}