blob: 63726ddd3d128db42e90ce1fa3dd7ec885f4d307 [file] [log] [blame]
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +05301# PLDM daemon options
2option(
3 'tests',
4 type: 'feature',
5 value: 'enabled',
6 description: 'Build tests'
7)
Lei YU31fc47e2020-02-27 11:41:45 +08008
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +05309option(
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +053010 'utilities',
11 type: 'feature',
12 value: 'enabled',
13 description: 'Enable debug utilities'
14)
Brad Bishopadbb2452021-08-19 16:33:53 -040015
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +053016option(
17 'libpldmresponder',
18 type: 'feature',
19 value: 'enabled',
20 description: 'Enable libpldmresponder'
21)
Sagar Srinivasa6a8ccd2021-04-01 07:58:33 -050022
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +053023option(
24 'systemd',
25 type: 'feature',
26 value: 'enabled',
27 description: 'Include systemd support'
28)
Manojkiran Edacc5f1582021-09-29 17:03:06 +053029
Rashmica Gupta1ed5f7a2023-05-22 13:56:42 +100030option(
31 'transport-implementation',
32 type: 'combo',
33 choices: ['mctp-demux', 'af-mctp'],
34 description: 'transport via af-mctp or mctp-demux'
35)
36
vkaverap@in.ibm.comc0b0e7b2023-07-18 00:06:40 -050037# As per PLDM spec DSP0240 version 1.1.0, in Timing Specification for PLDM messages (Table 6),
38# the instance ID for a given response will expire and become reusable if a response has not been
39# received within a maximum of 6 seconds after a request is sent. By setting the dbus timeout
40# value to 5 seconds we ensure that PLDM does not wait for a response from a dbus call even after
41# the instance ID has expired. If the option is set to 5 seconds, any dbus call originated from
42# PLDM daemon will timeout after 5 seconds.
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +053043option(
44 'dbus-timeout-value',
45 type: 'integer',
46 min: 3,
47 max: 10,
48 value: 5,
49 description: '''The amount of time pldm waits to get a response for a dbus
50 message before timing out'''
51)
52
53option(
54 'heartbeat-timeout-seconds',
55 type: 'integer',
56 value: 120,
57 description: '''The amount of time host waits for BMC to respond to pings
58 from host, as part of host-bmc surveillance'''
59)
60
61# Flight Recorder for PLDM Daemon
62option(
63 'flightrecorder-max-entries',
64 type:'integer',
65 min:0,
66 max:30,
67 value: 10,
68 description: '''The max number of pldm messages that can be stored in the
69 recorder, this feature will be disabled if it is set to 0'''
70)
71
72# PLDM Daemon Terminus options
73option(
74 'terminus-id',
75 type:'integer',
76 min:0,
77 max: 255,
78 value:1,
79 description: '''The terminus id value of the device that is running this
80 pldm stack'''
81)
82
83option(
84 'terminus-handle',
85 type:'integer',
86 min:0,
87 max:65535,
88 value:1,
89 description: '''The terminus handle value of the device that is running this
90 pldm stack'''
91)
92
93# Timing specification options for PLDM messages
94option(
95 'number-of-request-retries',
96 type: 'integer',
97 min: 2,
98 max: 30,
99 value: 2,
100 description: '''The number of times a requester is obligated to retry a
101 request'''
102)
103
104option(
105 'instance-id-expiration-interval',
106 type: 'integer',
107 min: 5,
108 max: 6,
109 value: 5,
110 description: 'Instance ID expiration interval in seconds'
111)
112
113# Default response-time-out set to 2 seconds to facilitate a minimum retry of
114# the request of 2.
115option(
116 'response-time-out',
117 type: 'integer',
118 min: 300,
119 max: 4800,
120 value: 2000,
121 description: '''The amount of time a requester has to wait for a response
122 message in milliseconds'''
123)
Manojkiran Edacc5f1582021-09-29 17:03:06 +0530124
Tom Josephef90b0d2021-08-17 07:12:49 -0700125# Firmware update configuration parameters
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +0530126option(
127 'maximum-transfer-size',
128 type: 'integer',
129 min: 16,
130 max: 4294967295,
131 value: 4096,
132 description: '''Maximum size in bytes of the variable payload allowed to be
133 requested by the FD, via RequestFirmwareData command'''
134)
135
Archana Kakani46f352e2024-03-17 08:21:08 -0500136# Bios Attributes option
137option(
138 'system-specific-bios-json',
139 type : 'feature',
140 value: 'disabled',
141 description : 'Support for different set of bios attributes for different types of systems'
142)
143
Manojkiran Edae8fd5fb2023-07-14 18:39:08 +0530144# PLDM Soft Power off options
145option(
146 'softoff',
147 type: 'feature',
148 value: 'enabled',
149 description: 'Build soft power off application'
150)
151
152option(
153 'softoff-timeout-seconds',
154 type: 'integer',
155 value: 7200,
156 description: 'softoff: Time to wait for host to gracefully shutdown'
157)
158
159# Vendor Specific Options
160
161## OEM IBM Options
162option(
163 'oem-ibm',
164 type: 'feature',
165 value: 'enabled',
166 description: 'Enable IBM OEM PLDM'
167)
168
169option(
170 'oem-ibm-dma-maxsize',
171 type: 'integer',
172 min:4096,
173 max: 16773120,
174 value: 8384512,
175 description: 'OEM-IBM: max DMA size'
176)
Thu Nguyen3c5486d2024-08-01 08:03:08 +0000177
178## Default Sensor Update Interval Options
179option(
180 'default-sensor-update-interval',
181 type: 'integer',
182 min: 1,
183 max: 4294967295,
184 description: '''The default sensor polling interval in milliseconds.
185 The value will be used when the internal is not configured
186 in the PLDM sensor PDRs use `updateInterval` field. `pldmd`
187 will send `GetSensorReading` to get the PLDM sensor values
188 of the monitoring terminus after each configured
189 interval.''',
190 value: 999