| * Copyright © 2017 IBM Corporation |
| * |
| * Licensed under the Apache License, Version 2.0 (the "License"); |
| * you may not use this file except in compliance with the License. |
| * You may obtain a copy of the License at |
| * |
| * http://www.apache.org/licenses/LICENSE-2.0 |
| * |
| * Unless required by applicable law or agreed to in writing, software |
| * distributed under the License is distributed on an "AS IS" BASIS, |
| * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied. |
| * See the License for the specific language governing permissions and |
| * limitations under the License. |
| */ |
| #include <phosphor-logging/log.hpp> |
| #include <phosphor-logging/elog.hpp> |
| #include <xyz/openbmc_project/Sensor/Device/error.hpp> |
| #include <xyz/openbmc_project/Control/Device/error.hpp> |
| #include <xyz/openbmc_project/Power/Fault/error.hpp> |
| #include "elog-errors.hpp" |
| #include "names_values.hpp" |
| #include "power_supply.hpp" |
| #include "pmbus.hpp" |
| #include "utility.hpp" |
| |
| using namespace phosphor::logging; |
| using namespace sdbusplus::xyz::openbmc_project::Control::Device::Error; |
| using namespace sdbusplus::xyz::openbmc_project::Sensor::Device::Error; |
| using namespace sdbusplus::xyz::openbmc_project::Power::Fault::Error; |
| |
| namespace witherspoon |
| { |
| namespace power |
| { |
| namespace psu |
| { |
| |
| constexpr auto INVENTORY_OBJ_PATH = "/xyz/openbmc_project/inventory"; |
| constexpr auto INVENTORY_INTERFACE = "xyz.openbmc_project.Inventory.Item"; |
| constexpr auto PRESENT_PROP = "Present"; |
| constexpr auto POWER_OBJ_PATH = "/org/openbmc/control/power0"; |
| constexpr auto POWER_INTERFACE = "org.openbmc.control.Power"; |
| |
| PowerSupply::PowerSupply(const std::string& name, size_t inst, |
| const std::string& objpath, |
| const std::string& invpath, |
| sdbusplus::bus::bus& bus, |
| event::Event& e, |
| std::chrono::seconds& t) |
| : Device(name, inst), monitorPath(objpath), pmbusIntf(objpath), |
| inventoryPath(invpath), bus(bus), event(e), powerOnInterval(t), |
| powerOnTimer(e, [this]() |
| { |
| this->powerOn = true; |
| }) |
| { |
| using namespace sdbusplus::bus; |
| auto present_obj_path = INVENTORY_OBJ_PATH + inventoryPath; |
| presentMatch = std::make_unique<match_t>(bus, |
| match::rules::propertiesChanged( |
| present_obj_path, |
| INVENTORY_INTERFACE), |
| [this](auto& msg) |
| { |
| this->inventoryChanged(msg); |
| }); |
| // Get initial presence state. |
| updatePresence(); |
| |
| // Subscribe to power state changes |
| powerOnMatch = std::make_unique<match_t>(bus, |
| match::rules::propertiesChanged( |
| POWER_OBJ_PATH, |
| POWER_INTERFACE), |
| [this](auto& msg) |
| { |
| this->powerStateChanged(msg); |
| }); |
| // Get initial power state. |
| updatePowerState(); |
| } |
| |
| |
| void PowerSupply::analyze() |
| { |
| using namespace witherspoon::pmbus; |
| |
| try |
| { |
| if (present) |
| { |
| auto curUVFault = pmbusIntf.readBit(VIN_UV_FAULT, Type::Hwmon); |
| //TODO: 3 consecutive reads should be performed. |
| // If 3 consecutive reads are seen, log the fault. |
| // Driver gives cached value, read once a second. |
| // increment for fault on, decrement for fault off, to deglitch. |
| // If count reaches 3, we have fault. If count reaches 0, fault is |
| // cleared. |
| |
| auto curInputFault = pmbusIntf.readBit(INPUT_FAULT_WARN, |
| Type::Hwmon); |
| |
| if (curUVFault != vinUVFault) |
| { |
| vinUVFault = curUVFault; |
| |
| if (curUVFault) |
| { |
| std::uint16_t statusWord = 0; |
| statusWord = pmbusIntf.read(STATUS_WORD, Type::Debug); |
| |
| util::NamesValues nv; |
| nv.add("STATUS_WORD", statusWord); |
| |
| using metadata = xyz::openbmc_project::Power::Fault:: |
| PowerSupplyUnderVoltageFault; |
| |
| report<PowerSupplyUnderVoltageFault>( |
| metadata::RAW_STATUS(nv.get().c_str())); |
| |
| vinUVFault = true; |
| } |
| else |
| { |
| log<level::INFO>("VIN_UV_FAULT cleared", |
| entry("POWERSUPPLY=%s", |
| inventoryPath.c_str())); |
| } |
| |
| } |
| |
| if (curInputFault != inputFault) |
| { |
| if (curInputFault) |
| { |
| std::uint16_t statusWord = 0; |
| std::uint8_t statusInput = 0; |
| |
| statusWord = pmbusIntf.read(STATUS_WORD, Type::Debug); |
| statusInput = pmbusIntf.read(STATUS_INPUT, Type::Debug); |
| |
| util::NamesValues nv; |
| nv.add("STATUS_WORD", statusWord); |
| nv.add("STATUS_INPUT", statusInput); |
| |
| using metadata = xyz::openbmc_project::Power::Fault:: |
| PowerSupplyInputFault; |
| |
| report<PowerSupplyInputFault>( |
| metadata::RAW_STATUS(nv.get().c_str())); |
| |
| inputFault = true; |
| } |
| else |
| { |
| inputFault = false; |
| } |
| |
| } |
| } |
| } |
| catch (ReadFailure& e) |
| { |
| if (!readFailLogged) |
| { |
| commit<ReadFailure>(); |
| readFailLogged = true; |
| // TODO - Need to reset that to false at start of power on, or |
| // presence change. |
| } |
| } |
| |
| return; |
| } |
| |
| void PowerSupply::inventoryChanged(sdbusplus::message::message& msg) |
| { |
| std::string msgSensor; |
| std::map<std::string, sdbusplus::message::variant<uint32_t, bool>> msgData; |
| msg.read(msgSensor, msgData); |
| |
| // Check if it was the Present property that changed. |
| auto valPropMap = msgData.find(PRESENT_PROP); |
| if (valPropMap != msgData.end()) |
| { |
| present = sdbusplus::message::variant_ns::get<bool>(valPropMap->second); |
| |
| if (present) |
| { |
| readFailLogged = false; |
| vinUVFault = false; |
| inputFault = false; |
| } |
| } |
| |
| return; |
| } |
| |
| void PowerSupply::updatePresence() |
| { |
| // Use getProperty utility function to get presence status. |
| std::string path = INVENTORY_OBJ_PATH + inventoryPath; |
| std::string service = "xyz.openbmc_project.Inventory.Manager"; |
| |
| try |
| { |
| util::getProperty(INVENTORY_INTERFACE, PRESENT_PROP, path, |
| service, bus, this->present); |
| } |
| catch (std::exception& e) |
| { |
| // If we happen to be trying to update presence just as it is being |
| // updated, we may encounter a runtime_error. Just catch that for |
| // now, let the inventoryChanged signal handler update presence later. |
| present = false; |
| } |
| |
| } |
| |
| void PowerSupply::powerStateChanged(sdbusplus::message::message& msg) |
| { |
| int32_t state = 0; |
| std::string msgSensor; |
| std::map<std::string, sdbusplus::message::variant<int32_t, int32_t>> |
| msgData; |
| msg.read(msgSensor, msgData); |
| |
| // Check if it was the Present property that changed. |
| auto valPropMap = msgData.find("state"); |
| if (valPropMap != msgData.end()) |
| { |
| state = sdbusplus::message::variant_ns::get<int32_t>(valPropMap->second); |
| |
| // Power is on when state=1. Set the fault logged variables to false |
| // and start the power on timer when the state changes to 1. |
| if (state) |
| { |
| readFailLogged = false; |
| vinUVFault = false; |
| inputFault = false; |
| powerOnTimer.start(powerOnInterval, Timer::TimerType::oneshot); |
| } |
| else |
| { |
| powerOnTimer.stop(); |
| powerOn = false; |
| } |
| } |
| |
| } |
| |
| void PowerSupply::updatePowerState() |
| { |
| // When state = 1, system is powered on |
| int32_t state = 0; |
| |
| try |
| { |
| auto service = util::getService(POWER_OBJ_PATH, |
| POWER_INTERFACE, |
| bus); |
| |
| // Use getProperty utility function to get power state. |
| util::getProperty<int32_t>(POWER_INTERFACE, |
| "state", |
| POWER_OBJ_PATH, |
| service, |
| bus, |
| state); |
| |
| if (state) |
| { |
| powerOn = true; |
| } |
| else |
| { |
| powerOn = false; |
| } |
| } |
| catch (std::exception& e) |
| { |
| log<level::INFO>("Failed to get power state. Assuming it is off."); |
| powerOn = false; |
| } |
| |
| } |
| |
| void PowerSupply::clearFaults() |
| { |
| //TODO - Clear faults at pre-poweron. openbmc/openbmc#1736 |
| return; |
| } |
| |
| } |
| } |
| } |