| SUMMARY = "OpenBMC - Applications" |
| PR = "r1" |
| |
| inherit packagegroup |
| inherit obmc-phosphor-utils |
| inherit obmc-phosphor-license |
| |
| PROVIDES = "${PACKAGES}" |
| PACKAGES = " \ |
| ${PN}-bmc-state-mgmt \ |
| ${PN}-chassis-state-mgmt \ |
| ${PN}-extras \ |
| ${PN}-extrasdev \ |
| ${PN}-extrasdevtools \ |
| ${PN}-fan-control \ |
| ${PN}-host-state-mgmt \ |
| ${PN}-inventory \ |
| ${PN}-leds \ |
| ${PN}-sensors \ |
| ${PN}-software \ |
| ${PN}-host-check-mgmt \ |
| ${PN}-debug-collector \ |
| ${PN}-settings \ |
| ${PN}-network \ |
| ${PN}-user-mgmt \ |
| " |
| |
| SUMMARY_${PN}-bmc-state-mgmt = "BMC state management" |
| RDEPENDS_${PN}-bmc-state-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-state-manager} \ |
| " |
| |
| SUMMARY_${PN}-chassis-state-mgmt = "Chassis state management" |
| RDEPENDS_${PN}-chassis-state-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-chassis-state-manager} \ |
| " |
| |
| SUMMARY_${PN}-host-check-mgmt = "Host state check on bmc reset" |
| RDEPENDS_${PN}-host-check-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-host-check} \ |
| " |
| |
| SUMMARY_${PN}-extras = "Extra features" |
| RDEPENDS_${PN}-extras = " \ |
| phosphor-rest \ |
| phosphor-dbus-monitor \ |
| " |
| |
| SUMMARY_${PN}-extrasdev = "Development features" |
| RDEPENDS_${PN}-extrasdev = " \ |
| rest-dbus \ |
| " |
| |
| SUMMARY_${PN}-extrasdevtools = "Development tools" |
| RDEPENDS_${PN}-extrasdevtools = " \ |
| " |
| |
| # Use the fan control package group for applications |
| # implementing fan control or system fan policy only. |
| # Applications that create inventory or sensors should |
| # be added those respective package groups instead. |
| SUMMARY_${PN}-fan-control = "Fan control" |
| RDEPENDS_${PN}-fan-control = " \ |
| ${VIRTUAL-RUNTIME_obmc-fan-control} \ |
| phosphor-fan-monitor \ |
| " |
| |
| SUMMARY_${PN}-host-state-mgmt = "Host state management" |
| RDEPENDS_${PN}-host-state-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-host-state-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-discover-system-state} \ |
| " |
| |
| SUMMARY_${PN}-inventory = "Inventory applications" |
| RDEPENDS_${PN}-inventory = " \ |
| ${VIRTUAL-RUNTIME_obmc-inventory-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-fan-presence} \ |
| " |
| |
| SUMMARY_${PN}-leds = "LED applications" |
| RDEPENDS_${PN}-leds = " \ |
| ${VIRTUAL-RUNTIME_obmc-leds-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-leds-sysfs} \ |
| ${VIRTUAL-RUNTIME_obmc-led-monitor} \ |
| " |
| |
| SUMMARY_${PN}-sensors = "Sensor applications" |
| RDEPENDS_${PN}-sensors = " \ |
| ${VIRTUAL-RUNTIME_obmc-sensors-hwmon} \ |
| " |
| |
| # These packages are not required with UBI enabled |
| ${PN}-software-extras = " \ |
| obmc-flash-bmc \ |
| obmc-mgr-download \ |
| " |
| |
| ${PN}-software-extras_df-obmc-ubi-fs = "" |
| |
| SUMMARY_${PN}-software = "Software applications" |
| RDEPENDS_${PN}-software = " \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-download-mgr} \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-updater} \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-version} \ |
| ${${PN}-software-extras} \ |
| " |
| |
| SUMMARY_${PN}-debug-collector = "BMC debug collector" |
| RDEPENDS_${PN}-debug-collector = " \ |
| ${VIRTUAL-RUNTIME_obmc-dump-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-dump-monitor} \ |
| phosphor-debug-collector-dreport \ |
| phosphor-debug-collector-scripts \ |
| " |
| |
| SUMMARY_${PN}-settings = "Settings applications" |
| RDEPENDS_${PN}-settings = " \ |
| ${VIRTUAL-RUNTIME_obmc-settings-mgmt} \ |
| " |
| |
| SUMMARY_${PN}-network = "BMC Network Manager" |
| RDEPENDS_${PN}-network = " \ |
| ${VIRTUAL-RUNTIME_obmc-network-manager} \ |
| " |
| |
| SUMMARY_${PN}-user-mgmt = "User management applications" |
| RDEPENDS_${PN}-user-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-user-mgmt} \ |
| " |