| SUMMARY = "OpenBMC - Applications" |
| PR = "r1" |
| |
| inherit packagegroup |
| |
| PROVIDES = "${PACKAGES}" |
| PACKAGES = " \ |
| ${PN}-bmc-state-mgmt \ |
| ${PN}-bmcweb \ |
| ${PN}-chassis-state-mgmt \ |
| ${PN}-console \ |
| ${PN}-dbus-monitor \ |
| ${PN}-extras \ |
| ${PN}-devtools \ |
| ${PN}-fan-control \ |
| ${PN}-fru-ipmi \ |
| ${PN}-health-monitor \ |
| ${PN}-host-state-mgmt \ |
| ${PN}-ikvm \ |
| ${PN}-inventory \ |
| ${PN}-leds \ |
| ${PN}-logging \ |
| ${PN}-remote-logging \ |
| ${PN}-rng \ |
| ${PN}-sensors \ |
| ${PN}-software \ |
| ${PN}-host-check-mgmt \ |
| ${PN}-debug-collector \ |
| ${PN}-settings \ |
| ${PN}-network \ |
| ${PN}-telemetry \ |
| ${PN}-user-mgmt \ |
| ${PN}-user-mgmt-ldap \ |
| " |
| |
| SUMMARY_${PN}-bmc-state-mgmt = "BMC state management" |
| RDEPENDS_${PN}-bmc-state-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-state-manager} \ |
| phosphor-state-manager-systemd-target-monitor \ |
| obmc-targets \ |
| " |
| |
| SUMMARY_${PN}-bmcweb = "bmcweb support" |
| RDEPENDS_${PN}-bmcweb = " \ |
| bmcweb \ |
| phosphor-bmcweb-cert-config \ |
| " |
| |
| SUMMARY_${PN}-chassis-state-mgmt = "Chassis state management" |
| RDEPENDS_${PN}-chassis-state-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-chassis-state-manager} \ |
| obmc-phosphor-power \ |
| " |
| |
| SUMMARY_${PN}-console = "Serial over LAN support" |
| RDEPENDS_${PN}-console = " \ |
| obmc-console \ |
| " |
| |
| # Deprecated - add new packages to an existing packagegroup or create a new one. |
| SUMMARY_${PN}-extras = "Extra features" |
| RDEPENDS_${PN}-extras = "" |
| |
| SUMMARY_${PN}-devtools = "Development tools" |
| RDEPENDS_${PN}-devtools = " \ |
| bash \ |
| ffdc \ |
| i2c-tools \ |
| libgpiod-tools \ |
| lrzsz \ |
| rsync \ |
| " |
| |
| SUMMARY_${PN}-dbus-monitor = "Support for dbus monitoring" |
| RDEPENDS_${PN}-dbus-monitor = " \ |
| phosphor-dbus-monitor \ |
| " |
| |
| # Use the fan control package group for applications |
| # implementing fan control or system fan policy only. |
| # Applications that create inventory or sensors should |
| # be added those respective package groups instead. |
| SUMMARY_${PN}-fan-control = "Fan control" |
| RDEPENDS_${PN}-fan-control = " \ |
| ${VIRTUAL-RUNTIME_obmc-fan-control} \ |
| phosphor-fan-monitor \ |
| " |
| |
| SUMMARY_${PN}-fru-ipmi = "Support for EEPROMS with IPMI FRU" |
| RDEPENDS_${PN}-fru-ipmi = " \ |
| fru-device \ |
| " |
| |
| SUMMARY_${PN}-health-monitor = "Support for health monitoring" |
| RDEPENDS_${PN}-health-monitor = " \ |
| phosphor-health-monitor \ |
| " |
| |
| SUMMARY_${PN}-host-state-mgmt = "Host state management" |
| RDEPENDS_${PN}-host-state-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-host-state-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-discover-system-state} \ |
| " |
| |
| SUMMARY_${PN}-ikvm = "KVM over IP support" |
| RDEPENDS_${PN}-ikvm = " \ |
| obmc-ikvm \ |
| " |
| |
| SUMMARY_${PN}-inventory = "Inventory applications" |
| RDEPENDS_${PN}-inventory = " \ |
| ${VIRTUAL-RUNTIME_obmc-inventory-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-fan-presence} \ |
| " |
| |
| SUMMARY_${PN}-leds = "LED applications" |
| RDEPENDS_${PN}-leds = " \ |
| ${VIRTUAL-RUNTIME_obmc-leds-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-leds-sysfs} \ |
| ${VIRTUAL-RUNTIME_obmc-led-monitor} \ |
| " |
| |
| SUMMARY_${PN}-logging = "Logging applications" |
| RDEPENDS_${PN}-logging = " \ |
| phosphor-logging \ |
| " |
| |
| SUMMARY_${PN}-remote-logging = "Remote logging applications" |
| RDEPENDS_${PN}-remote-logging = " \ |
| rsyslog \ |
| phosphor-rsyslog-config \ |
| " |
| |
| SUMMARY_${PN}-rng = "Random Number Generator support" |
| RDEPENDS_${PN}-rng = " \ |
| rng-tools \ |
| " |
| |
| SUMMARY_${PN}-sensors = "Sensor applications" |
| RDEPENDS_${PN}-sensors = " \ |
| ${VIRTUAL-RUNTIME_obmc-sensors-hwmon} \ |
| " |
| |
| ${PN}-software-extras = "" |
| |
| ${PN}-software-extras_df-obmc-ubi-fs = " \ |
| phosphor-software-manager-updater-ubi \ |
| " |
| |
| ${PN}-software-extras_df-phosphor-mmc = " \ |
| phosphor-software-manager-updater-mmc \ |
| " |
| |
| SUMMARY_${PN}-software = "Software applications" |
| RDEPENDS_${PN}-software = " \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-download-mgr} \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-updater} \ |
| ${VIRTUAL-RUNTIME_obmc-bmc-version} \ |
| ${${PN}-software-extras} \ |
| " |
| |
| SUMMARY_${PN}-debug-collector = "BMC debug collector" |
| RDEPENDS_${PN}-debug-collector = " \ |
| ${VIRTUAL-RUNTIME_obmc-dump-manager} \ |
| ${VIRTUAL-RUNTIME_obmc-dump-monitor} \ |
| phosphor-debug-collector-dreport \ |
| phosphor-debug-collector-scripts \ |
| " |
| |
| SUMMARY_${PN}-settings = "Settings applications" |
| RDEPENDS_${PN}-settings = " \ |
| phosphor-settings-manager \ |
| " |
| |
| SUMMARY_${PN}-network = "BMC Network Manager" |
| RDEPENDS_${PN}-network = " \ |
| ${VIRTUAL-RUNTIME_obmc-network-manager} \ |
| " |
| |
| SUMMARY_${PN}-telemetry = "Telemetry solution" |
| RDEPENDS_${PN}-telemetry = " \ |
| telemetry \ |
| " |
| |
| SUMMARY_${PN}-user-mgmt = "User management applications" |
| RDEPENDS_${PN}-user-mgmt = " \ |
| ${VIRTUAL-RUNTIME_obmc-user-mgmt} \ |
| " |
| RRECOMMENDS_${PN}-user-mgmt = " \ |
| pam-plugin-access \ |
| " |
| |
| SUMMARY_${PN}-user-mgmt-ldap = "LDAP users and groups support" |
| RDEPENDS_${PN}-user-mgmt-ldap = " \ |
| ${PN}-user-mgmt \ |
| nss-pam-ldapd \ |
| phosphor-ldap \ |
| phosphor-nslcd-cert-config \ |
| phosphor-nslcd-authority-cert-config \ |
| " |