blob: 862d4587cc81ab3e893f5658acb5901674ed7941 [file] [log] [blame]
*** Settings ***
Documentation This example demonstrates executing commands on a remote machine
... and getting their output and the return code.
...
... Notice how connections are handled as part of the suite setup and
... teardown. This saves some time when executing several test cases.
Resource ../lib/rest_client.robot
Resource ../lib/ipmi_client.robot
Resource ../lib/openbmc_ffdc.robot
Resource ../lib/state_manager.robot
Library ../data/model.py
Resource ../lib/boot_utils.robot
Resource ../lib/utils.robot
Suite Setup Setup The Suite
Test Setup Open Connection And Log In
Test Teardown Post Test Case Execution
*** Variables ***
${stack_mode} skip
${model}= ${OPENBMC_MODEL}
*** Test Cases ***
Verify connection
Execute new Command echo "hello"
Response Should Be Equal "hello"
Execute ipmi BT capabilities command
[Tags] Execute_ipmi_BT_capabilities_command
Run IPMI command 0x06 0x36
response Should Be Equal " 01 40 40 0a 01"
Execute Set Sensor Boot Count
[Tags] Execute_Set_Sensor_Boot_Count
${uri}= Get System component BootCount
${x}= Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x01 0x00 0x35 0x00 0x00 0x00 0x00 0x00 0x00
Read the Attribute ${uri} value
${val}= convert to integer 53
Response Should Be Equal ${val}
OCC Active Sensor On Enabled
[Tags] OCC_Active_Sensor_On_Enabled
${uri}= Get System component OccStatus
${x}= Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x02 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} value
Response Should Be Equal Enabled
OCC Active Sensor On Disabled
[Tags] OCC_Active_Sensor_On_Disabled
${uri}= Get System component OccStatus
${x}= Get Sensor Number ${uri}
Run IPMI command 0x04 0x30 ${x} 0x00 0x00 0x01 0x00 0x00 0x00 0x00 0x20 0x00
Read The Attribute ${uri} value
Response Should Be Equal Disabled
Verify OCC Power Supply Redundancy
[Documentation] Check if OCC's power supply is set to not redundant.
[Tags] Verify_OCC_Power_Supply_Redundancy
${uri}= Get System Component PowerSupplyRedundancy
Read The Attribute ${uri} value
Response Should Be Equal Disabled
Verify OCC Power Supply Derating Value
[Documentation] Check if OCC's power supply derating value
... is set correctly to a constant value 10.
[Tags] Verify_OCC_Power_Supply_Derating_Value
${uri}= Get System Component PowerSupplyDerating
Read The Attribute ${uri} value
Response Should Be Equal ${10}
Verify Enabling OCC Turbo Setting Via IPMI
[Documentation] Set and verify OCC's turbo allowed on enable.
# The allowed value for turbo allowed:
# True - To enable turbo allowed.
# False - To disable turbo allowed.
[Setup] Turbo Setting Test Case Setup
[Tags] Verify_Enabling_OCC_Turbo_Setting_Via_IPMI
[Teardown] Restore System Configuration
${uri}= Get System Component TurboAllowed
${sensor_num}= Get Sensor Number ${uri}
${ipmi_cmd}= Catenate SEPARATOR= 0x04 0x30 ${sensor_num} 0x00${SPACE}
... 0x00 0x01 0x00 0x00 0x00 0x00 0x20 0x00
Run IPMI Command ${ipmi_cmd}
Read The Attribute ${uri} value
Response Should Be Equal True
Verify Disabling OCC Turbo Setting Via IPMI
[Documentation] Set and verify OCC's turbo allowed on disable.
# The allowed value for turbo allowed:
# True - To enable turbo allowed.
# False - To disable turbo allowed.
[Setup] Turbo Setting Test Case Setup
[Tags] Verify_Disabling_OCC_Turbo_Setting_Via_IPMI
[Teardown] Restore System Configuration
${uri}= Get System Component TurboAllowed
${sensor_num}= Get Sensor Number ${uri}
${ipmi_cmd}= Catenate SEPARATOR= 0x04 0x30 ${sensor_num} 0x00${SPACE}
... 0x00 0x00 0x00 0x01 0x00 0x00 0x20 0x00
Run IPMI Command ${ipmi_cmd}
Read The Attribute ${uri} value
Response Should Be Equal False
Verify Setting OCC Turbo Via REST
[Documentation] Verify enabling and disabling OCC's turbo allowed
... via REST.
# The allowed value for turbo allowed:
# True - To enable turbo allowed.
# False - To disable turbo allowed.
[Setup] Turbo Setting Test Case Setup
[Tags] Verify_Setting_OCC_Turbo_Via_REST
[Teardown] Restore System Configuration
Set Turbo Setting Via REST False
${setting}= Read Turbo Setting Via REST
Should Be Equal ${setting} False
Set Turbo Setting Via REST True
${setting}= Read Turbo Setting Via REST
Should Be Equal ${setting} True
io_board Present
[Tags] io_board_Present
${uri}= Get System component io_board
Read The Attribute ${uri} present
Response Should Be Equal True
io_board Fault
[Tags] io_board_Fault
${uri}= Get System component io_board
Read The Attribute ${uri} fault
Response Should Be Equal False
*** Keywords ***
Setup The Suite
[Documentation] Initial suite setup.
# Boot Host.
REST Power On
Open Connection And Log In
${resp}= Read Properties ${OPENBMC_BASE_URI}enumerate timeout=30
Set Suite Variable ${SYSTEM_INFO} ${resp}
log Dictionary ${resp}
Turbo Setting Test Case Setup
[Documentation] Open Connection and turbo settings
Open Connection And Log In
${setting}= Read Turbo Setting Via REST
Set Global Variable ${TURBO_SETTING} ${setting}
Get System component
[Arguments] ${type}
${list}= Get Dictionary Keys ${SYSTEM_INFO}
${resp}= Get Matches ${list} regexp=^.*[0-9a-z_].${type}[0-9]*$
${url}= Get From List ${resp} 0
[Return] ${url}
Execute new Command
[Arguments] ${args}
${output}= Execute Command ${args}
set test variable ${OUTPUT} "${output}"
response Should Be Equal
[Arguments] ${args}
Should Be Equal ${OUTPUT} ${args}
Response Should Be Empty
Should Be Empty ${OUTPUT}
Read the Attribute
[Arguments] ${uri} ${parm}
${output}= Read Attribute ${uri} ${parm}
set test variable ${OUTPUT} ${output}
Get Sensor Number
[Arguments] ${name}
${x}= get sensor ${OPENBMC_MODEL} ${name}
[Return] ${x}
Get Inventory Sensor Number
[Arguments] ${name}
${x}= get inventory sensor ${OPENBMC_MODEL} ${name}
[Return] ${x}
Post Test Case Execution
[Documentation] Do the post test teardown.
... 1. Capture FFDC on test failure.
... 2. Close all open SSH connections.
FFDC On Test Case Fail
Close All Connections
Restore System Configuration
[Documentation] Restore System Configuration.
Open Connection And Log In
Set Turbo Setting Via REST ${TURBO_SETTING}
Close All Connections