*** Settings ***
Documentation Utilities for fan tests.
Library ../lib/bmc_ssh_utils.py
Variables ../data/variables.py
*** Keywords ***
Is Water Cooled
[Documentation] Return 1 if system is water cooled, 0 othersise.
${water_cooled}= Read Attribute
... ${HOST_INVENTORY_URI}/system/chassis WaterCooled
[Return] ${water_cooled}
Get Number Of Fans
[Documentation] Get the number of fans currently present in inventory.
${num_fans} Set Variable ${0}
${fan_uris}= Get Endpoint Paths ${HOST_INVENTORY_URI}/system fan
: FOR ${fan_uri} IN @{fan_uris}
\ ${fan_record}= Read Properties ${fan_uri}
\ Continue For Loop If ${fan_record['Present']} != 1
\ ${num_fans}= Set Variable ${num_fans+1}
[Return] ${num_fans}
Verify Minimum Number Of Fans With Cooling Type
[Documentation] Verify minimum number of fans.
[Arguments] ${water_cooled}
# Description of argument(s):
# water_cooled The value 1 if the system is water cooled,
# the value 0 if air cooled.
# For a water cooled system.
${min_fans_water}= Set Variable 2
# For an air cooled system.
${min_fans_air}= Set Variable 3
${num_fans}= Get Number Of Fans
Rprintn
Rpvars water_cooled num_fans
# If water cooled must have at least min_fans_water fans, otherwise
# issue Fatal Error and terminate testing.
Run Keyword If ${water_cooled} == 1 and ${num_fans} < ${min_fans_water}
... Fatal Error
... msg=Water cooled but less than ${min_fans_water} fans present.
# If air cooled must have at least min_fans_air fans.
Run Keyword If ${water_cooled} == 0 and ${num_fans} < ${min_fans_air}
... Fatal Error
... msg=Air cooled but less than ${min_fans_air} fans present.
Verify Fan Monitors With State
[Documentation] Verify fan monitor daemons in the system state.
# The number of monitoring daemons is dependent upon the system
# power state. If power is off there should be 0, if power
# is on there should be several.
[Arguments] ${power_state}
# Description of argument(s):
# power_state Power staet of the system, either "On" or "Off"
${cmd}= Catenate systemctl list-units | grep phosphor-fan | wc -l
${num_fan_daemons} ${stderr} ${rc}= BMC Execute Command ${cmd}
Rpvars power_state num_fan_daemons
# Fail if system is On and there are no fan monitors.
Run Keyword If '${power_state}' == 'On' and ${num_fan_daemons} == 0
... Fail msg=No phosphor-fan monitors found at power on.
# Fail if system is Off and the fan monitors are present.
Run Keyword If '${power_state}' == 'Off' and ${num_fan_daemons} != 0
... Fail msg=Phosphor-fan monitors found at power off.