| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 1 | *** Settings *** | 
| Gunnar Mills | 917ba1a | 2018-04-08 16:42:12 -0500 | [diff] [blame] | 2 | Documentation   Suite to test hardware sensors. | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 3 |  | 
 | 4 | Resource        ../lib/utils.robot | 
 | 5 | Resource        ../lib/boot_utils.robot | 
 | 6 | Resource        ../lib/state_manager.robot | 
 | 7 | Resource        ../lib/openbmc_ffdc.robot | 
| George Keishing | dcf746b | 2018-02-06 12:43:44 -0600 | [diff] [blame] | 8 | Resource        ../lib/ipmi_client.robot | 
 | 9 | Variables       ../data/ipmi_raw_cmd_table.py | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 10 |  | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 11 | Suite Setup     Suite Setup Execution | 
 | 12 | Test Teardown   Test Teardown Execution | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 13 |  | 
 | 14 | *** Test Cases *** | 
 | 15 |  | 
| Steven Sombar | eabeccf | 2018-09-06 11:41:12 -0500 | [diff] [blame] | 16 |  | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 17 | Verify System Ambient Temperature | 
 | 18 |     [Documentation]  Check the ambient sensor temperature. | 
 | 19 |     [Tags]  Verify_System_Ambient_Temperature | 
 | 20 |  | 
 | 21 |     # Example: | 
 | 22 |     # /xyz/openbmc_project/sensors/temperature/ambient | 
 | 23 |     # { | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 24 |     #     "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC", | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 25 |     #     "Value": 25.767 | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 26 |     # } | 
 | 27 |  | 
 | 28 |     ${temp_data}=  Read Properties  ${SENSORS_URI}temperature/ambient | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 29 |     Should Be Equal As Strings | 
 | 30 |     ...  ${temp_data["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.DegreesC | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 31 |     Should Be True  ${temp_data["Value"]} <= ${50} | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 32 |     ...  msg=System working temperature crossed 50 degree celsius. | 
 | 33 |  | 
| Steven Sombar | eabeccf | 2018-09-06 11:41:12 -0500 | [diff] [blame] | 34 |  | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 35 | Verify Fan Sensors Attributes | 
 | 36 |    [Documentation]  Check fan attributes. | 
| George Keishing | ac8661e | 2022-02-10 00:36:12 -0600 | [diff] [blame] | 37 |    [Tags]  Verify_Fan_Sensors_Attributes | 
| George Keishing | 28f7405 | 2020-07-20 09:02:50 -0500 | [diff] [blame] | 38 |  | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 39 |    # Example: | 
| George Keishing | 28f7405 | 2020-07-20 09:02:50 -0500 | [diff] [blame] | 40 |    # "/xyz/openbmc_project/sensors/fan_tach/fan0_0", | 
 | 41 |    # "/xyz/openbmc_project/sensors/fan_tach/fan0_1", | 
 | 42 |    # "/xyz/openbmc_project/sensors/fan_tach/fan1_0", | 
 | 43 |    # "/xyz/openbmc_project/sensors/fan_tach/fan1_1", | 
 | 44 |    # "/xyz/openbmc_project/sensors/fan_tach/fan2_0", | 
 | 45 |    # "/xyz/openbmc_project/sensors/fan_tach/fan2_1", | 
 | 46 |    # "/xyz/openbmc_project/sensors/fan_tach/fan3_0", | 
 | 47 |    # "/xyz/openbmc_project/sensors/fan_tach/fan3_1" | 
 | 48 |  | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 49 |    ${fans}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  fan* | 
 | 50 |  | 
 | 51 |    # Access the properties of the fan and it should contain | 
 | 52 |    # the following entries: | 
| George Keishing | 28f7405 | 2020-07-20 09:02:50 -0500 | [diff] [blame] | 53 |    # /xyz/openbmc_project/sensors/fan_tach/fan0_0 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 54 |    # { | 
| George Keishing | 28f7405 | 2020-07-20 09:02:50 -0500 | [diff] [blame] | 55 |    #     "Functional": true, | 
 | 56 |    #     "MaxValue": 0.0, | 
 | 57 |    #     "MinValue": 0.0, | 
 | 58 |    #     "Target": 10500, | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 59 |    #     "Unit": "xyz.openbmc_project.Sensor.Value.Unit.RPMS", | 
| George Keishing | 28f7405 | 2020-07-20 09:02:50 -0500 | [diff] [blame] | 60 |    #     "Value": 0.0 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 61 |    # } | 
 | 62 |  | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 63 |    FOR  ${entry}  IN  @{fans} | 
 | 64 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 65 |      ${json}=  To JSON  ${resp.content} | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 66 |      Run Keyword And Ignore Error  Should Be True  ${json["data"]["Target"]} >= 0 | 
| George Keishing | 28f7405 | 2020-07-20 09:02:50 -0500 | [diff] [blame] | 67 |      Run Keyword And Ignore Error  Should Be Equal As Strings | 
 | 68 |      ...  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.RPMS | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 69 |      Should Be True  ${json["data"]["Value"]} >= 0 | 
 | 70 |    END | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 71 |  | 
 | 72 | Verify PCIE Sensors Attributes | 
 | 73 |    [Documentation]  Probe PCIE attributes. | 
| George Keishing | ac8661e | 2022-02-10 00:36:12 -0600 | [diff] [blame] | 74 |    [Tags]  Verify_PCIE_Sensors_Attributes | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 75 |    # Example: | 
 | 76 |    # /xyz/openbmc_project/sensors/temperature/pcie | 
 | 77 |    ${temp_pcie}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  pcie | 
 | 78 |  | 
 | 79 |    # Access the properties of the PCIE and it should contain | 
 | 80 |    # the following entries: | 
 | 81 |    # /xyz/openbmc_project/sensors/temperature/pcie | 
 | 82 |    # { | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 83 |    #    "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC", | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 84 |    #    "Value": 29.625 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 85 |    # } | 
 | 86 |  | 
 | 87 |  | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 88 |    FOR  ${entry}  IN  @{temp_pcie} | 
 | 89 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 90 |      ${json}=  To JSON  ${resp.content} | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 91 |      Should Be Equal As Strings  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.DegreesC | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 92 |      Should Be True  ${json["data"]["Value"]} > 0 | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 93 |    END | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 94 |  | 
 | 95 |  | 
 | 96 | Verify Rail Voltage Sensors Attributes | 
 | 97 |    [Documentation]  Check rail voltage attributes. | 
| George Keishing | ac8661e | 2022-02-10 00:36:12 -0600 | [diff] [blame] | 98 |    [Tags]  Verify_Rail_Voltage_Sensors_Attributes | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 99 |    # Example of one of the entries returned by 'Get Endpoint Paths': | 
 | 100 |    # /xyz/openbmc_project/sensors/voltage/rail_1_voltage | 
 | 101 |    # /xyz/openbmc_project/sensors/voltage/rail_2_voltage | 
 | 102 |    ${temp_rail}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  rail* | 
 | 103 |  | 
 | 104 |    # Example: | 
 | 105 |    # Access the properties of the rail voltage and it should contain | 
 | 106 |    # the following entries: | 
 | 107 |    # "/xyz/openbmc_project/sensors/voltage/rail_1_voltage": | 
 | 108 |    # { | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 109 |    #    "Unit": "xyz.openbmc_project.Sensor.Value.Unit.Volts", | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 110 |    #    "Value": 5.097 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 111 |    # }, | 
 | 112 |  | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 113 |    FOR  ${entry}  IN  @{temp_rail} | 
 | 114 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 115 |      ${json}=  To JSON  ${resp.content} | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 116 |      Should Be Equal As Strings  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.Volts | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 117 |      Should Be True  ${json["data"]["Value"]} > 0 | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 118 |    END | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 119 |  | 
 | 120 |  | 
 | 121 | Verify VDN Temperature Sensors Attributes | 
 | 122 |    [Documentation]  Check vdn temperature attributes. | 
 | 123 |    [Tags]  Verify_VDN_Temperature_Sensors_Attributes | 
 | 124 |    # Example of one of the entries returned by 'Get Endpoint Paths': | 
 | 125 |    # /xyz/openbmc_project/sensors/temperature/p0_vdn_temp | 
 | 126 |    ${temp_vdn}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  *_vdn_temp | 
 | 127 |  | 
 | 128 |    # Example: | 
 | 129 |    # Access the properties of the rail voltage and it should contain | 
 | 130 |    # the following entries: | 
 | 131 |    # /xyz/openbmc_project/sensors/temperature/p0_vdn_temp | 
 | 132 |    # { | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 133 |    #    "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC", | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 134 |    #    "Value": 3.000 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 135 |    # } | 
 | 136 |  | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 137 |    FOR  ${entry}  IN  @{temp_vdn} | 
 | 138 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 139 |      ${json}=  To JSON  ${resp.content} | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 140 |      Should Be Equal As Strings  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.DegreesC | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 141 |      Should Be True  ${json["data"]["Value"]} > 0 | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 142 |    END | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 143 |  | 
 | 144 | Verify VCS Temperature Sensors Attributes | 
 | 145 |    [Documentation]  Check vcs temperature attributes. | 
 | 146 |    [Tags]  Verify_VCS_Temperature_Sensors_Attributes | 
 | 147 |    # Example of one of the entries returned by 'Get Endpoint Paths': | 
 | 148 |    # /xyz/openbmc_project/sensors/temperature/p0_vcs_temp | 
 | 149 |    ${temp_vcs}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  *_vcs_temp | 
 | 150 |  | 
 | 151 |    # Example: | 
 | 152 |    # Access the properties of the rail voltage and it should contain | 
 | 153 |    # the following entries: | 
 | 154 |    # /xyz/openbmc_project/sensors/temperature/p0_vcs_temp | 
 | 155 |    # { | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 156 |    #     "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC", | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 157 |    #     "Value": 31.000 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 158 |    # }, | 
 | 159 |  | 
 | 160 |  | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 161 |    FOR  ${entry}  IN  @{temp_vcs} | 
 | 162 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 163 |      ${json}=  To JSON  ${resp.content} | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 164 |      Should Be Equal As Strings  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.DegreesC | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 165 |      Should Be True  ${json["data"]["Value"]} > 0 | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 166 |    END | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 167 |  | 
 | 168 |  | 
 | 169 | Verify VDD Temperature Sensors Attributes | 
 | 170 |    [Documentation]  Check vdd temperature attributes. | 
 | 171 |    [Tags]  Verify_VDD_Temperature_Sensors_Attributes | 
 | 172 |    # Example of one of the entries returned by 'Get Endpoint Paths': | 
 | 173 |    # /xyz/openbmc_project/sensors/temperature/p0_vdd_temp | 
 | 174 |    ${temp_vdd}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  *_vdd_temp | 
 | 175 |  | 
 | 176 |    # Example: | 
 | 177 |    # Access the properties of the rail voltage and it should contain | 
 | 178 |    # the following entries: | 
 | 179 |    # /xyz/openbmc_project/sensors/temperature/p0_vdd_temp | 
 | 180 |    # { | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 181 |    #     "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC", | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 182 |    #     "Value": 4.000 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 183 |    # } | 
 | 184 |  | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 185 |    FOR  ${entry}  IN  @{temp_vdd} | 
 | 186 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 187 |      ${json}=  To JSON  ${resp.content} | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 188 |      Should Be Equal As Strings  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.DegreesC | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 189 |      Should Be True  ${json["data"]["Value"]} > 0 | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 190 |    END | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 191 |  | 
 | 192 |  | 
 | 193 | Verify VDDR Temperature Sensors Attributes | 
 | 194 |    [Documentation]  Check vddr temperature attributes. | 
 | 195 |    [Tags]  Verify_VDDR_Temperature_Sensors_Attributes | 
 | 196 |    # Example of one of the entries returned by 'Get Endpoint Paths': | 
 | 197 |    # /xyz/openbmc_project/sensors/temperature/p0_vddr_temp | 
 | 198 |    ${temp_vddr}= | 
 | 199 |    ...  Get Endpoint Paths  /xyz/openbmc_project/sensors/  *_vddr_temp | 
 | 200 |  | 
 | 201 |    # Example: | 
 | 202 |    # Access the properties of the rail voltage and it should contain | 
 | 203 |    # the following entries: | 
 | 204 |    # /xyz/openbmc_project/sensors/temperature/p0_vddr_temp | 
 | 205 |    # { | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 206 |    #     "Unit": "xyz.openbmc_project.Sensor.Value.Unit.DegreesC", | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 207 |    #     "Value": 4.000 | 
| Sweta Potthuri | cca07de | 2017-09-26 06:14:23 -0500 | [diff] [blame] | 208 |    # } | 
 | 209 |  | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 210 |    FOR  ${entry}  IN  @{temp_vddr} | 
 | 211 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 212 |      ${json}=  To JSON  ${resp.content} | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 213 |      Should Be Equal As Strings  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.DegreesC | 
| Konstantin Aladyshev | 2ac4d4f | 2021-03-20 23:36:39 +0300 | [diff] [blame] | 214 |      Should Be True  ${json["data"]["Value"]} > 0 | 
| Sushil Singh | 5dbaf9d | 2020-06-19 05:43:20 -0500 | [diff] [blame] | 215 |    END | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 216 |  | 
| Jayashree-D | ea98230 | 2020-07-21 16:44:13 +0530 | [diff] [blame] | 217 | Verify Power Sensors Attributes | 
 | 218 |    [Documentation]  Check power sensor attributes. | 
| George Keishing | ac8661e | 2022-02-10 00:36:12 -0600 | [diff] [blame] | 219 |    [Tags]  Verify_Power_Sensors_Attributes | 
| Jayashree-D | ea98230 | 2020-07-21 16:44:13 +0530 | [diff] [blame] | 220 |    # Example: | 
 | 221 |    # /xyz/openbmc_project/sensors/power/power_1 | 
 | 222 |    # /xyz/openbmc_project/sensors/power/power_2 | 
 | 223 |    # /xyz/openbmc_project/sensors/power/power0 | 
 | 224 |    # /xyz/openbmc_project/sensors/power/POWER1 | 
 | 225 |    # /xyz/openbmc_project/sensors/power/POWER_1 | 
 | 226 |  | 
 | 227 |    ${power}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  power* | 
 | 228 |  | 
 | 229 |    # Access the properties of the power sensors and it should contain | 
 | 230 |    # the following entries: | 
 | 231 |    # /xyz/openbmc_project/sensors/power/power_1 | 
 | 232 |    # { | 
 | 233 |    #     "MaxValue": 255.0, | 
 | 234 |    #     "MinValue": 0.0, | 
 | 235 |    #     "Unit": "xyz.openbmc_project.Sensor.Value.Unit.Watts", | 
 | 236 |    #     "Value": 0.0 | 
 | 237 |    # } | 
 | 238 |  | 
 | 239 |    FOR  ${entry}  IN  @{power} | 
 | 240 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 241 |      ${json}=  To JSON  ${resp.content} | 
 | 242 |      Run Keyword And Ignore Error  Should Be True  ${json["data"]["Target"]} >= 0 | 
 | 243 |      Should Be True  ${json["data"]["Value"]} >= 0 | 
 | 244 |    END | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 245 |  | 
| Jayashree-D | fe793fa | 2020-07-27 20:26:09 +0530 | [diff] [blame] | 246 |  | 
 | 247 | Verify Voltage Sensors Attributes | 
 | 248 |    [Documentation]  Check voltage sensors attributes. | 
| George Keishing | ac8661e | 2022-02-10 00:36:12 -0600 | [diff] [blame] | 249 |    [Tags]  Verify_Voltage_Sensors_Attributes | 
| Jayashree-D | fe793fa | 2020-07-27 20:26:09 +0530 | [diff] [blame] | 250 |  | 
 | 251 |    # Example: | 
 | 252 |    # "/xyz/openbmc_project/sensors/voltage/voltage0", | 
| George Keishing | 16b3c7b | 2021-01-28 09:23:37 -0600 | [diff] [blame] | 253 |    # "/xyz/openbmc_project/sensors/voltage/voltage_1", | 
| Jayashree-D | fe793fa | 2020-07-27 20:26:09 +0530 | [diff] [blame] | 254 |    # "/xyz/openbmc_project/sensors/voltage/VOLTAGE_2", | 
 | 255 |    # "/xyz/openbmc_project/sensors/voltage/VOLTAGE1", | 
 | 256 |    # "/xyz/openbmc_project/sensors/voltage/voltage". | 
 | 257 |  | 
 | 258 |    ${voltage}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/voltage/  * | 
 | 259 |  | 
 | 260 |    # Access the properties of the voltage sensors and it should contain | 
 | 261 |    # the following entries: | 
 | 262 |    # /xyz/openbmc_project/sensors/voltage/voltage0 | 
 | 263 |    # { | 
 | 264 |    #     "MaxValue": 255.0, | 
 | 265 |    #     "MinValue": 0.0, | 
 | 266 |    #     "Unit": xyz.openbmc_project.Sensor.Value.Unit.Volts | 
 | 267 |    #     "Value": 0.0 | 
 | 268 |    # } | 
 | 269 |  | 
 | 270 |    FOR  ${entry}  IN  @{voltage} | 
 | 271 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 272 |      ${json}=  To JSON  ${resp.content} | 
 | 273 |      Run Keyword And Ignore Error  Should Be Equal As Strings | 
 | 274 |      ...  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.Volts | 
 | 275 |      Run Keyword And Ignore Error  Should Be True  ${json["data"]["Value"]} >= 0 | 
 | 276 |    END | 
 | 277 |  | 
 | 278 |  | 
 | 279 | Verify Current Sensors Attributes | 
 | 280 |    [Documentation]  Check current sensors attributes. | 
| George Keishing | ac8661e | 2022-02-10 00:36:12 -0600 | [diff] [blame] | 281 |    [Tags]  Verify_Current_Sensors_Attributes | 
| Jayashree-D | fe793fa | 2020-07-27 20:26:09 +0530 | [diff] [blame] | 282 |  | 
 | 283 |    # Example: | 
 | 284 |    # "/xyz/openbmc_project/sensors/current/current0", | 
 | 285 |    # "/xyz/openbmc_project/sensors/current/current_1", | 
 | 286 |    # "/xyz/openbmc_project/sensors/current/CURRENT_2", | 
 | 287 |    # "/xyz/openbmc_project/sensors/current/CURRENT1", | 
 | 288 |    # "/xyz/openbmc_project/sensors/current/current". | 
 | 289 |  | 
 | 290 |    ${current}=  Get Endpoint Paths  /xyz/openbmc_project/sensors/  curr* | 
 | 291 |  | 
 | 292 |    # Access the properties of the current sensors and it should contain | 
 | 293 |    # the following entries: | 
 | 294 |    # /xyz/openbmc_project/sensors/current/current0 | 
 | 295 |    # { | 
 | 296 |    #     "MaxValue": 255.0, | 
 | 297 |    #     "MinValue": 0.0, | 
 | 298 |    #     "Unit": xyz.openbmc_project.Sensor.Value.Unit.Amperes | 
 | 299 |    #     "Value": 0.0 | 
 | 300 |    # } | 
 | 301 |  | 
 | 302 |    FOR  ${entry}  IN  @{current} | 
 | 303 |      ${resp}=  OpenBMC Get Request  ${entry} | 
 | 304 |      ${json}=  To JSON  ${resp.content} | 
 | 305 |      Run Keyword And Ignore Error  Should Be Equal As Strings | 
 | 306 |      ...  ${json["data"]["Unit"]}  xyz.openbmc_project.Sensor.Value.Unit.Amperes | 
 | 307 |      Should Be True  ${json["data"]["Value"]} >= 0 | 
 | 308 |    END | 
 | 309 |  | 
 | 310 |  | 
| Steven Sombar | eabeccf | 2018-09-06 11:41:12 -0500 | [diff] [blame] | 311 | Verify Power Redundancy Using REST | 
 | 312 |    [Documentation]  Verify power redundancy is enabled. | 
 | 313 |    [Tags]  Verify_Power_Redundancy_Using_REST | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 314 |  | 
 | 315 |    # Example: | 
 | 316 |    # /xyz/openbmc_project/sensors/chassis/PowerSupplyRedundancy | 
 | 317 |    # { | 
 | 318 |    #     "error": 0, | 
 | 319 |    #     "units": "", | 
 | 320 |    #     "value": "Enabled" | 
 | 321 |    # } | 
 | 322 |  | 
| Steven Sombar | eabeccf | 2018-09-06 11:41:12 -0500 | [diff] [blame] | 323 |    # Power Redundancy is a read-only attribute.  It cannot be set. | 
| Steven Sombar | 27c1ad4 | 2018-09-11 14:44:25 -0500 | [diff] [blame] | 324 |  | 
 | 325 |    # Pass if sensor is in /xyz and it's enabled. | 
 | 326 |    ${redundancy_setting}=  Read Attribute | 
 | 327 |    ...  ${OPENBMC_BASE_URI}control/power_supply_redundancy | 
 | 328 |    ...  PowerSupplyRedundancyEnabled | 
 | 329 |    Should Be Equal As Integers  ${redundancy_setting}  ${1} | 
 | 330 |    ...  msg=PowerSupplyRedundancyEnabled not set as expected. | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 331 |  | 
 | 332 |  | 
| Steven Sombar | eabeccf | 2018-09-06 11:41:12 -0500 | [diff] [blame] | 333 | Verify Power Redundancy Using IPMI | 
| Steven Sombar | 27c1ad4 | 2018-09-11 14:44:25 -0500 | [diff] [blame] | 334 |     [Documentation]  Verify IPMI reports Power Redundancy is enabled. | 
| Steven Sombar | eabeccf | 2018-09-06 11:41:12 -0500 | [diff] [blame] | 335 |     [Tags]  Verify_Power_Redundancy_Using_IPMI | 
| George Keishing | dcf746b | 2018-02-06 12:43:44 -0600 | [diff] [blame] | 336 |  | 
 | 337 |     # Refer to data/ipmi_raw_cmd_table.py for command definition. | 
| Steven Sombar | eabeccf | 2018-09-06 11:41:12 -0500 | [diff] [blame] | 338 |     # Power Redundancy is a read-only attribute.  It cannot be set. | 
| George Keishing | dcf746b | 2018-02-06 12:43:44 -0600 | [diff] [blame] | 339 |  | 
 | 340 |     ${output}=  Run IPMI Standard Command | 
 | 341 |     ...  raw ${IPMI_RAW_CMD['power_supply_redundancy']['Get'][0]} | 
 | 342 |  | 
| Steven Sombar | 27c1ad4 | 2018-09-11 14:44:25 -0500 | [diff] [blame] | 343 |     ${scanning}=  Set Variable | 
 | 344 |     ...  ${IPMI_RAW_CMD['power_supply_redundancy']['Get'][5]} | 
 | 345 |     ${no_scanning}=  Set Variable | 
| George Keishing | dcf746b | 2018-02-06 12:43:44 -0600 | [diff] [blame] | 346 |     ...  ${IPMI_RAW_CMD['power_supply_redundancy']['Get'][3]} | 
| Steven Sombar | 27c1ad4 | 2018-09-11 14:44:25 -0500 | [diff] [blame] | 347 |  | 
 | 348 |     ${enabled_scanning}=  Evaluate  $scanning in $output | 
 | 349 |     ${enabled_no_scanning}=  Evaluate  $no_scanning in $output | 
 | 350 |  | 
 | 351 |     # Either enabled_scanning or enabled_noscanning should be True. | 
 | 352 |     Should Be True  ${enabled_scanning} or ${enabled_no_scanning} | 
 | 353 |     ...  msg=Failed IPMI power redundancy check, result=${output}. | 
| George Keishing | dcf746b | 2018-02-06 12:43:44 -0600 | [diff] [blame] | 354 |  | 
 | 355 |  | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 356 | *** Keywords *** | 
 | 357 |  | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 358 | Suite Setup Execution | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 359 |     [Documentation]  Do the initial test suite setup. | 
 | 360 |     # - Power off. | 
 | 361 |     # - Boot Host. | 
 | 362 |     REST Power Off  stack_mode=skip | 
 | 363 |     REST Power On | 
 | 364 |  | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 365 | Test Teardown Execution | 
| George Keishing | 0657247 | 2017-09-01 11:33:01 -0500 | [diff] [blame] | 366 |     [Documentation]  Do the post test teardown. | 
 | 367 |     # - Capture FFDC on test failure. | 
 | 368 |     # - Delete error logs. | 
 | 369 |     # - Close all open SSH connections. | 
 | 370 |  | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 371 |     FFDC On Test Case Fail | 
| George Keishing | 32fe4e1 | 2018-07-13 05:06:47 -0500 | [diff] [blame] | 372 |     Delete All Error Logs | 
| George Keishing | 8bf8ed7 | 2017-12-07 04:01:45 -0600 | [diff] [blame] | 373 |     Close All Connections |