George Keishing | 50cd001 | 2017-09-14 12:23:41 -0500 | [diff] [blame] | 1 | *** Settings *** |
| 2 | Documentation Suite to test OCC power module. |
| 3 | |
| 4 | Resource ../lib/open_power_utils.robot |
| 5 | Resource ../lib/boot_utils.robot |
| 6 | Resource ../lib/state_manager.robot |
| 7 | Resource ../lib/openbmc_ffdc.robot |
| 8 | |
| 9 | Suite Setup Suite Setup Execution |
| 10 | Test Teardown Test Teardown Execution |
| 11 | |
| 12 | *** Test Cases *** |
| 13 | |
| 14 | Verify OCC Object Count |
| 15 | [Documentation] Verify that OCC and inventory entries match. |
| 16 | [Tags] Verify_OCC_Object_Count |
| 17 | |
| 18 | # Example: |
| 19 | # /org/open_power/control/enumerate |
| 20 | # { |
| 21 | # "/org/open_power/control/host0": {}, |
| 22 | # "/org/open_power/control/occ0": { |
| 23 | # "OccActive": 0 |
| 24 | # }, |
| 25 | # "/org/open_power/control/occ1": { |
| 26 | # "OccActive": 0 |
| 27 | # } |
| 28 | # } |
| 29 | |
| 30 | # Inventory counterpart cpu's: |
| 31 | # "/xyz/openbmc_project/inventory/system/chassis/motherboard/cpu0", |
| 32 | # "/xyz/openbmc_project/inventory/system/chassis/motherboard/cpu1", |
| 33 | |
| 34 | ${inventory_count}= Count Object Entries |
| 35 | ... ${HOST_INVENTORY_URI}system/chassis/motherboard/ cpu* |
| 36 | |
| 37 | Should Be Equal ${occ_count} ${inventory_count} |
| 38 | ... msg=OCC and inventory entry counts are mismatched. |
| 39 | |
| 40 | |
| 41 | Verify OCC Active State |
| 42 | [Documentation] Check OCC active state. |
| 43 | [Tags] Verify_OCC_Active_State |
| 44 | |
| 45 | # Example cpu_list data output: |
| 46 | # /xyz/openbmc_project/inventory/system/chassis/motherboard/cpu0 |
| 47 | # /xyz/openbmc_project/inventory/system/chassis/motherboard/cpu1 |
| 48 | ${cpu_list}= Get Endpoint Paths |
| 49 | ... ${HOST_INVENTORY_URI}system/chassis/motherboard/ cpu* |
| 50 | |
| 51 | :FOR ${endpoint_path} IN @{cpu_list} |
| 52 | \ ${is_functional}= Read Object Attribute ${endpoint_path} Functional |
| 53 | \ Continue For Loop If ${is_functional} == ${0} |
| 54 | \ ${num}= Set Variable ${endpoint_path[-1]} |
| 55 | \ ${occ_active}= Get OCC Active State ${OPENPOWER_CONTROL}occ${num} |
| 56 | \ Should Be True ${occ_active} msg=OCC ${num} is not active. |
| 57 | |
| 58 | |
| 59 | *** Keywords *** |
| 60 | |
| 61 | Suite Setup Execution |
| 62 | [Documentation] Do the initial test suite setup. |
| 63 | # - Power off. |
| 64 | # - Boot Host. |
| 65 | |
| 66 | Smart Power Off |
| 67 | REST Power On |
| 68 | Count OCC Object Entry |
| 69 | |
| 70 | |
| 71 | Count OCC Object Entry |
| 72 | [Documentation] Count OCC object entry and set count. |
| 73 | |
| 74 | ${object_count}= Count Object Entries ${OPENPOWER_CONTROL} occ* |
| 75 | Set Suite Variable ${occ_count] ${object_count} |
| 76 | |
| 77 | |
| 78 | Test Teardown Execution |
| 79 | [Documentation] Do the post test teardown. |
| 80 | # - Capture FFDC on test failure. |
| 81 | # - Delete error logs. |
| 82 | # - Close all open SSH connections. |
| 83 | |
| 84 | FFDC On Test Case Fail |
| 85 | Delete Error Logs |
| 86 | Close All Connections |
| 87 | |