blob: 9a88428fc45c2c2e7b95cb0014ecba27a9234c65 [file] [log] [blame]
George Keishing92abc992016-10-18 13:29:25 -05001*** Settings ***
2Documentation Power cycle loop. This is to test where network service
3... becomes unavailable during AC-Cycle stress test.
4
5Resource ../lib/rest_client.robot
6Resource ../lib/pdu/pdu.robot
7Resource ../lib/utils.robot
8Resource ../lib/openbmc_ffdc.robot
George Keishingca709b02017-02-02 11:38:19 -06009Resource ../lib/state_manager.robot
George Keishingbf1500d2017-10-30 12:47:47 -050010Resource ../lib/boot_utils.robot
George Keishingc26e74d2017-11-17 00:45:20 -060011Resource ../lib/code_update_utils.robot
George Keishing9867bed2018-02-04 22:31:36 -060012Library ../lib/bmc_ssh_utils.py
George Keishing92abc992016-10-18 13:29:25 -050013
George Keishing94659a22017-11-17 00:03:05 -060014Test Teardown Test Teardown Execution
George Keishingc26e74d2017-11-17 00:45:20 -060015Suite Setup Suite Setup Execution
George Keishing92abc992016-10-18 13:29:25 -050016
17*** Variables ***
George Keishing397846b2020-04-28 03:55:53 -050018${LOOP_COUNT} ${50}
19${CHECK_FOR_ERRORS} ${1}
George Keishing92abc992016-10-18 13:29:25 -050020
George Keishing2c891732018-09-18 07:39:59 -050021# Error strings to check from journald.
George Keishing5b8ff522019-09-05 11:15:41 -050022${ERROR_REGEX} SEGV|core-dump|FAILURE|Failed to start
George Keishing2c891732018-09-18 07:39:59 -050023
George Keishing92abc992016-10-18 13:29:25 -050024*** Test Cases ***
25
George Keishingca709b02017-02-02 11:38:19 -060026Run Multiple Power Cycle
27 [Documentation] Execute multiple power cycles.
28 [Setup] Validate Parameters
29 [Tags] Run_Multiple_Power_Cycle
George Keishing92abc992016-10-18 13:29:25 -050030
George Keishingca709b02017-02-02 11:38:19 -060031 # By default run test for 50 loops, else user input iteration.
32 # Fails immediately if any of the execution rounds fail and
33 # check if BMC is still pinging and FFDC is collected.
34 Repeat Keyword ${LOOP_COUNT} times Power Cycle System Via PDU
35
36
George Keishing5d5b8a22019-09-11 13:48:54 -050037Run Multiple BMC Reset Via Redfish
George Keishingbf1500d2017-10-30 12:47:47 -050038 [Documentation] Execute multiple reboots via REST.
George Keishing5d5b8a22019-09-11 13:48:54 -050039 [Tags] Run_Multiple_BMC_Reset_Via_Redfish
George Keishingbf1500d2017-10-30 12:47:47 -050040
41 # By default run test for 50 loops, else user input iteration.
42 # Fails immediately if any of the execution rounds fail and
43 # check if BMC is still pinging and FFDC is collected.
George Keishing5d5b8a22019-09-11 13:48:54 -050044 Repeat Keyword ${LOOP_COUNT} times BMC Redfish Reset Cycle
George Keishingbf1500d2017-10-30 12:47:47 -050045
46
47Run Multiple BMC Reset Via Reboot
48 [Documentation] Execute multiple reboots via "reboot" command.
49 [Tags] Run_Multiple_BMC_Reset_Via_Reboot
George Keishingca709b02017-02-02 11:38:19 -060050
51 # By default run test for 50 loops, else user input iteration.
52 # Fails immediately if any of the execution rounds fail and
53 # check if BMC is still pinging and FFDC is collected.
54 Repeat Keyword ${LOOP_COUNT} times BMC Reboot Cycle
George Keishing92abc992016-10-18 13:29:25 -050055
56
57*** Keywords ***
58
George Keishingca709b02017-02-02 11:38:19 -060059Power Cycle System Via PDU
60 [Documentation] Power cycle system and wait for BMC to reach Ready state.
George Keishing5d5b8a22019-09-11 13:48:54 -050061
George Keishing92abc992016-10-18 13:29:25 -050062 PDU Power Cycle
George Keishingca709b02017-02-02 11:38:19 -060063 Check If BMC Is Up 5 min 10 sec
George Keishing92abc992016-10-18 13:29:25 -050064
George Keishingca709b02017-02-02 11:38:19 -060065 Wait Until Keyword Succeeds 10 min 10 sec Is BMC Ready
George Keishingb39a6792017-11-10 22:58:52 -060066 Verify BMC RTC And UTC Time Drift
George Keishingca709b02017-02-02 11:38:19 -060067
68
George Keishing5d5b8a22019-09-11 13:48:54 -050069BMC Redfish Reset Cycle
70 [Documentation] Reset BMC via Redfish and verify required states.
71
72 Redfish OBMC Reboot (off)
George Keishing397846b2020-04-28 03:55:53 -050073
George Keishing5d5b8a22019-09-11 13:48:54 -050074 ${bmc_version}= Get BMC Version
George Keishing397846b2020-04-28 03:55:53 -050075 Valid Value bmc_version valid_values=['${initial_bmc_version}']
76
77 Run Keyword If '${CHECK_FOR_ERRORS}' == '${1}'
78 ... Check For Regex In Journald ${ERROR_REGEX} error_check=${0} boot=-b
79
George Keishingb39a6792017-11-10 22:58:52 -060080 Verify BMC RTC And UTC Time Drift
George Keishing92abc992016-10-18 13:29:25 -050081
82
George Keishingbf1500d2017-10-30 12:47:47 -050083BMC Reboot Cycle
84 [Documentation] Reboot BMC and wait for ready state.
George Keishing5d5b8a22019-09-11 13:48:54 -050085
George Keishingbf1500d2017-10-30 12:47:47 -050086 OBMC Reboot (off) stack_mode=normal
George Keishing5d5b8a22019-09-11 13:48:54 -050087 ${bmc_version}= Get BMC Version
George Keishing9aa2f0b2019-09-18 09:49:48 -050088 Valid Value bmc_version ["${initial_bmc_version}"]
George Keishingb39a6792017-11-10 22:58:52 -060089 Verify BMC RTC And UTC Time Drift
George Keishingef3308b2019-09-28 10:50:33 -050090 Check For Regex In Journald ${ERROR_REGEX} error_check=${0} boot=-b
George Keishing5d5b8a22019-09-11 13:48:54 -050091 ${boot_side}= Get BMC Flash Chip Boot Side
92 Valid Value boot_side ['0']
George Keishingbf1500d2017-10-30 12:47:47 -050093
94
George Keishing94659a22017-11-17 00:03:05 -060095Test Teardown Execution
96 [Documentation] Do test case tear-down.
George Keishing92abc992016-10-18 13:29:25 -050097 Ping Host ${OPENBMC_HOST}
Gunnar Millseac1af22016-11-14 15:30:09 -060098 FFDC On Test Case Fail
George Keishing92abc992016-10-18 13:29:25 -050099
100
101Validate Parameters
George Keishing94659a22017-11-17 00:03:05 -0600102 [Documentation] Validate PDU parameters.
George Keishing92abc992016-10-18 13:29:25 -0500103 Should Not Be Empty ${PDU_IP}
104 Should Not Be Empty ${PDU_TYPE}
105 Should Not Be Empty ${PDU_SLOT_NO}
106 Should Not Be Empty ${PDU_USERNAME}
107 Should Not Be Empty ${PDU_PASSWORD}
108
George Keishingc26e74d2017-11-17 00:45:20 -0600109
110Suite Setup Execution
George Keishing5d5b8a22019-09-11 13:48:54 -0500111 [Documentation] Do suite setup.
112
113 ${bmc_version}= Get BMC Version
114 Set Suite Variable ${initial_bmc_version} ${bmc_version}