| # Supported BMC layout types. Reference: |
| # https://github.com/openbmc/docs/blob/master/architecture/code-update/flash-layout.md#supported-filesystem-choices |
| # - static: NOR flash configured with fixed-sized MTD partitions. |
| # - ubi: NOR flash device configured with UBI volumes. |
| # - mmc: eMMC flash device configured with ext4 filesystems. |
| option('bmc-layout', type: 'combo', |
| choices: ['static', 'ubi', 'mmc'], |
| value: 'static', |
| description: 'The BMC layout type.') |
| |
| # Features |
| option('host-bios-upgrade', type: 'feature', value: 'enabled', |
| description: 'Enable host bios upgrade support.') |
| |
| option('sync-bmc-files', type: 'feature', value: 'enabled', |
| description: 'Enable sync of filesystem files.') |
| |
| option('tests', type: 'feature', description: 'Build tests') |
| |
| option('oe-sdk', type: 'feature', description: 'Enable OE SDK') |
| |
| option('verify-signature', type: 'feature', value: 'enabled', |
| description: 'LEGACY: Use verify-full-signature instead. Enable image signature validation.') |
| |
| option('verify-full-signature', type: 'feature', value: 'enabled', |
| description: 'Enable image full signature validation.') |
| |
| # Variables |
| option( |
| 'active-bmc-max-allowed', type: 'integer', |
| value: 1, |
| description: 'The maximum allowed active BMC versions.', |
| ) |
| |
| option( |
| 'hash-file-name', type: 'string', |
| value: 'hashfunc', |
| description: 'The name of the hash file.', |
| ) |
| |
| option( |
| 'img-upload-dir', type: 'string', |
| value: '/tmp/images', |
| description: 'Directory where downloaded software images are placed.', |
| ) |
| |
| option( |
| 'manifest-file-name', type: 'string', |
| value: 'MANIFEST', |
| description: 'The name of the MANIFEST file.', |
| ) |
| |
| option( |
| 'media-dir', type: 'string', |
| value: '/run/media', |
| description: 'The base dir where all read-only partitions are mounted.', |
| ) |
| |
| option( |
| 'optional-images', type: 'array', |
| value: [], |
| description: 'A list of additional image files in the BMC tarball.', |
| ) |
| |
| option( |
| 'publickey-file-name', type: 'string', |
| value: 'publickey', |
| description: 'The name of the public key file.', |
| ) |
| |
| option( |
| 'signature-file-ext', type: 'string', |
| value: '.sig', |
| description: 'The extension of the Signature file.', |
| ) |
| |
| option( |
| 'signed-image-conf-path', type: 'string', |
| value: '/etc/activationdata/', |
| description: 'Path of public key and hash function files.', |
| ) |
| |
| option( |
| 'sync-list-dir-path', type: 'string', |
| value: '/etc/', |
| description: 'The path to the sync list file directory.', |
| ) |
| |
| option( |
| 'sync-list-file-name', type: 'string', |
| value: 'synclist', |
| description: 'The name of the sync list file.', |
| ) |
| |
| option( |
| 'bmc-msl', type: 'string', |
| value: '', |
| description: 'The BMC minimum ship level.', |
| ) |
| |
| option( |
| 'regex-bmc-msl', type: 'string', |
| value: '', |
| description: 'The Regular expression to parse the MSL.', |
| ) |
| |
| option( |
| 'bios-object-path', type: 'string', |
| value: '/xyz/openbmc_project/software/bios_active', |
| description: 'The BIOS DBus object path.', |
| ) |